My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01157 - mechanical
Orono
>
Property Files
>
Street Address
>
K
>
Kelly Avenue
>
2560 Kelly Avenue - 20-117-23-11-0007
>
Permits/Inspections
>
2015-01157 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:47:24 PM
Creation date
3/31/2017 1:09:23 PM
Metadata
Fields
Template:
x Address Old
House Number
2560
Street Name
Kelly
Street Type
Avenue
Address
2560 Kelly Avenue
Document Type
Permits/Inspections
PIN
2011723110007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEP/10/2015/THU 02: 19 PM Flare Heating FAX No, 7635423101 P. 005 <br /> `Rltvac-Residential&Light Corr�m�rcial HVAC,Loaiis �Ilte 5oftvuarab.Pveiopnient,Inc: <br /> F1are�Heatiltg,8,AfC lnC., , , . <br /> Golden V _ �'.. ` , ` <br /> Pro ect Re ort <br /> '"•' ei��c�"•"W�a._wr�iG'c��F'���''r�r;sv'F•rir �.�. +�,a�' f: "',i:::xt.: C ,:;;��; <br /> �..x.�,.. <br /> Project Title: <br /> Project Date; 9/8/2014 <br /> Project Comment: <br /> Comp�ny N�me: Flare Hesting And Air Gonditioning <br /> Company Representative� JustEn Graff <br /> Company Address: 9303 Plymouth Ave No_Suite 104 <br /> Company Ciry: Golden Valley, MN 55427 <br /> Company Phone: (612)986-44B5 <br /> ,r .��, r�M. <br /> Reference City: Minneapolis/St. Paul AP,Minnesata <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> �atitude; 44 Degrees <br /> ElevaHon� 834 R. <br /> Altitude Factor� 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> D�qr�tl�i W�t F3ulb $�j,�p1 $�I.Hum Dhv Bulb Dl�ference <br /> Winter: -13 -11.42 n/a n/a 72 n/a <br /> Summer� 92 71 36% 50% 7'2 24 <br /> �s <br /> Total Building Supply CFM: 2,357 CFM Per Square ft_� 0.470 '� <br /> Square ft.of Room Area: 5,012 Square ft.Per Ton: 1 p2g "* <br /> Volume(fta)of Cond,Sp�ce� (htg.) 49,270 <br /> ° Based on area of rooms being heated or cooled(whichever governs system}ra#her fhan antire flaor area. <br /> "'�Based on area of roams being coofed. <br /> r d., _ as�' +' <br /> Totaf Heating Required Inciudfng Ventllation Air. 56,456 Stuh 86.456 MBH <br /> Total 5ensibfe Gain: 43,198 Btuh $9 % <br /> 'Total Latent Gain: 5,366 Btuh 11 % <br /> Total Cooling Required Including Ventilation Air. 48,564 Btuh 4.05 Tons{Based On Sensible*Late�t) <br /> o , <br /> Rhvac is an ACCA approved Manual,!and Manual D computer pragram. <br /> Calculations are parformed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary, <br /> Be sure to select a unit tha#meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C'1...11MF House 2560 Kelly Ave Excelsior MN.rh9 Thursday, May 28,2015, 10:12 AM <br />