My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-01133 - sprinkler system
Orono
>
Property Files
>
Street Address
>
K
>
Kelley Parkway
>
2730 Kelley Parkway - 33-118-23-12-0007
>
Permits/Inspections
>
2014-01133 - sprinkler system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:42 PM
Creation date
3/28/2017 12:23:03 PM
Metadata
Fields
Template:
x Address Old
House Number
2700
Street Name
Kelley
Street Type
Parkway
Address
2700 Kelley Parkway
Document Type
Permits/Inspections
PIN
3311823120007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- � - � - � - i � � � o <br /> . . . . <br /> UO �ully Listed and FM Approved Sprir�kler Pipe -� � <br /> .. <br /> When you spedfy Schedule-14/Schedule-40-M-COATO sprinkler pipe Trom NPs Nominal Nominal I.D. Nominal ,Wt. WC(H2OFiiled) cRe <br /> AlliedTube&Conduit, ou et UL listed and FM a roved Codu�tS.Althou h �";mm O.D.In;mm �n�mm Wallin mm LbslF•k m �bslFTk m <br /> Y 9 PP p � 1" 1.315 1.044 0.133 1.680 2A5 1 <br /> these products do not require separate approvals,Schedule-10/Schedule-40- zs 33.4 26.6 �.3s z:s 3.05 - <br /> M-COAT gives you the extra quality assurance you demand.Our Sch-10(1-1/4" �'���� 1.660 i.3so o.,ao z.no 2.93 , <br /> 32 42.1 35.1 3.56 3.39 4.36 <br /> -8")pipe and Sch-40(1"-2-1t2")pipe have passed the same thorough(ab ,v;° ,.soo �.e�o o.ias z.�zo 3.61 , <br /> testing as our ather listed pipe products,and reteive periodic mill inspections ao 483 ao.9 3.68 a.e s.3� - <br /> from both UL and FM agents to ensure cansistent qualiry. z" z,3i� z.o�r o.isa 3.bsb s.�s � <br /> 50 60.3 52.5 3.97 5.4 7.63 <br /> 2;5" 2.875 2.a69 0.203 5.80 7.86 7 <br /> � Superior Coatir�g 65 73 62] 5.16 8.6 11.73 - <br /> Our advanced formula mill coating offers a clean,durable surface that is also , . <br /> paintready for custom color appiications without special preparation. •' •� <br /> NPS Nominal Nominal I.D. Naminal • Wt Wt.(H20 Filed) CRR <br /> In mm O.D.In•mm In�mm Wall in mm L6slFt•k Lbs/Ft�k!m <br /> The intemal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter 1i" ib66 i.aaz 0.109 ,.s�o zszs zo9ss <br /> shall be coated with Allied Tube&Conduit Antibacterial Formula °M-COAT°. 3z az.a s�.� �:7� �.� s.7s - <br /> 1 bi" 1.900 1.682 0.109 2.09 3.04 5.6570 <br /> d0 48.3 42.7 2.77 3.1 4.52 <br /> d American Made 2" 2.375 2.157 0.109 2.640 4.21 4.5827 <br /> 50 603 54.8 2.77 3.9 6.28 - <br /> Manufactured at one of 3 U.S.Facilities and is available through distributors in z�,;�• z.s7s z.�ss o.,zo 3.530 s.e9 3s,�e <br /> the USA, Canada,Mexico,and Latin America. 6s �s 60.9 3.05 5.26 s.7� - <br /> >" 3.500 3.260 0.120 434 7.9-0 2.5550 <br /> 75 88.4 82.8 3.05 6.4 11,82 <br /> �" 4.500 4.260 4.120 5.62 11.78 1.6020 <br /> �' Specifications & Approvals 70Q 114.3 108.20 3.05 8.3 17.53 <br /> Schedule-10/Schedule-40 M-COAT � e are in com liance with the followin 5"` 5.563 5.295 0.134 7.78 n.33 ,.as�a <br /> p p p g• 125 141.3 134.5 3.40 11.58 25.80 - <br /> ASTM A135,Type E,Grade A,and NFPA 13.Both pipe products have a working 6"� 6.625 b357 aisu 9.s 23.03 �.ozs� <br /> pressure rating of 300 psi maximum and also meet the stringent requirement �so 168.3 �c,s 3.ao is.a sa.z7 - <br /> 8"` 8.625 8.249 0.185 16.96 4Q15 1.8365 <br /> for the follovving tests:Welded Outlets, Hydrostatic Pressure,Side Wall Rupture, zoo 219 209.50 a.7s zs.z 59.75 <br /> VibrHtion TeSt. *Not ava�lahle with M-Coat <br /> �� C >.L FM <br /> �LP�N6VHD <br /> Project: Sprinkler Contractor: Date: <br /> Engineer: Specification Reference: System Type: <br /> Locations: Comments: <br /> /'���I��� Customer Service:(800)882-5543 Fax: (800)659-7730 www.alliedtu e-sprinkler.com <br /> � � • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27t Ave. <br /> TUBE&CONDUIT° Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 5009 <br /> ,P.,� � atkOre c02013 Atkore International,Inc.All Rights Reserv d.STP-S3-4M-1301 <br />
The URL can be used to link to this page
Your browser does not support the video tag.