�. <br /> ' Orono Police Department <br /> Plumbing <br /> Plan No.PLB 1406-00246 <br /> Page 3 <br /> July 9,2014 <br /> 17. It is recommended that a cleanout be provided where new waste and vent piping connects wi h existing <br /> plumbing to facilita.te required testing of the new installation. <br /> 18. Each horizontal drain branch, including floor drain branches, shall be provided with a cleano t at its upper <br /> terminal with the following exceptions(see Minnesota Rules,part 4715.1000): <br /> a. A readily removable fixture trap or a fixture with an integral trap may be accepted as a c eanout. <br /> b. A floor drain cleanout may be omitted if the floor drain branch line is less than 5 feet. <br /> a Shower drain,mop sink, and receptor cleanouts may be on the fixture vent, or on the fix re. <br /> 19. Cross-link polyethylene(PEX)tubing must meet Minnesota Rules,part 4715.0520: <br /> a. When installed as a system in accordance with ASTM F877,the system tubing and fittin s must be of <br /> the same manufacturer and be marked as required. <br /> b. When not installed as a system,the fittings must be marked with ASTM F 1807,F 1960, 2080, <br /> F2098-01, or F2159. The tubing must list the fitting and tubing standard. <br /> c. Installers must be factory trained and possess a card documenting completion of trainmg <br /> 20. Materials used for subsoil drains must comply with Minnesota Rules,part 4715.0620. <br /> 21. Ductile iron pipe(DIl')water services must comply with ANSI A2115/AWWA C115 or <br /> ANSI A21.51/AWWA C151 (see Minnesota Rules,part 4715.0510). <br /> 22. PVC solvent w�ld joints must include a primer of contrasting color to the pipe and cement(se Minnesota <br /> Rules,part 4715.0810, subpart 2). <br /> 23. Above-grade horizontal plumbing piping must be supported as follows(see Minnesota Rules, <br /> part 4715.1430, subpart 4): <br /> a. Plastic pipe: at least every 32 inches. <br /> b. Copper tubing(1'/4-inch or less): at least every 6 feet. <br /> c. Copper tubing(1%z-inch or over): at least every 10 feet. <br /> 24. A full-way valve must be provided on the cold water supply line to the water heater(see Minn sota Rules, <br /> part 4715.1800). <br /> NOTE(S): <br /> 1. The scope of this project consists of the addition and remodeling to an existing building. The lumbing <br /> installation shall include catch basins and exterior storm water drainage piping,an infiltration asin, a <br /> ' flammable waste interceptor,two trench drains, floor drains,a shower, a dishwasher, an ice m er,a coffee <br /> maker, a washer box, a wall hydrant, hose bibbs, single and double compartment sinks, floor d ains,and <br /> restrooms. <br /> 2. This facility will be served by two new municipal sanitary sewer connections and an existing d new <br /> municipal water service. <br /> Authorization for construction in accordance with the approved plans may be withdrawn if construct on is not <br /> undertaken within a period of two years. The fact that the plans have been approved does not necess 'ly mean that <br /> recommendations or requirements for change will not be made at some later time when changed con itions, <br /> additional information,or advanced knowledge make improvements necessary. <br />