A non-structural steel special inspection final report-2015
Orono
>
Property Files
>
Street Address
>
K
>
Kelley Parkway
>
2730 Kelley Parkway - 33-118-23-12-0007
>
Misc
>
A non-structural steel special inspection final report-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:43 PM
Creation date
3/28/2017 11:58:14 AM
Metadata
Fields
Template:
x Address Old
House Number
2700
Street Name
Kelley
Street Type
Parkway
Address
2700 Kelley Parkway
Document Type
Misc
PIN
3311823120007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Kraus-Anderson Construction Company <br /> Project B14-05902 <br /> March 18, 2015 <br /> Page 3 <br /> Fresh Concrete Testing <br /> Routine tests to determine the plastic concrete's slump,temperature and air content were done during <br /> each pour. In addition, concrete cylinders were cast at rates specified in the project specifications to <br /> evaluate the concrete's compressive strength. <br /> Concrete Compressive Strength Testing <br /> The cast concrete cylinders were temporarily stored at the site and then returned to our laboratory for <br /> moist curing and testing.The results of the concrete compressive strength testing were forwarded to the <br /> interested parties under a separate cover as they became available. <br /> Masonry Construction Observations <br /> Prior to conducting the observations,the special inspector reviewed the construction documents and any <br /> associated approved submittals.As construction began,the proportions ofthe mortar, construction of <br /> mortarjoints and the location of reinforcement and connectors was observed for compliance with the <br /> requirements of the project plans and specifications. <br /> The inspection program included determining the size and location of structural elements in addition to <br /> the type, size, and location of anchors, including other details of anchorage of masonry to structural <br /> members,frames or other construction for compliance. We also determined if the specified size,grade <br /> and type of reinforcement was used and if the protection of masonry was in compliance with the <br /> guidelines of the IBC. <br /> Prior to grouting,the cleanliness of the grout space, placement of reinforcement and connectors, <br /> proportions of grout and construction of mortarjoints were observed. <br /> Concrete Masonry Grout Testing <br /> The grout prisms cast were tested in general accordance with ASTM C1019:Standard Test Method for <br /> Sampling and Testing Grout.The samples were temporarily stored at the site and returned to our <br /> laboratory for compressive strength testing.The results for the compressive strengths of the grout <br /> prisms were forwarded to the interested parties under separate cover as they became available. <br /> Drilled Epoxy Anchor Observations <br /> Observations were preformed during the installation of the drilled in epoxy anchors and to determine if <br /> they were installed according to the requirements of the manufacturer and the project documents. <br /> Items observed included the placement,depth of embedment, cleanliness of the drilled hole and <br /> application of the epoxy adhesive. The type of epoxy used was also documented for compliance with <br /> the requirements of the specifications. <br /> eRauN <br /> INT RTEC <br />
The URL can be used to link to this page
Your browser does not support the video tag.