Laserfiche WebLink
� Swedlund <br /> Se tic <br /> p <br /> Service <br /> To Whom It May Concern: �%/ ��� �'{� � <br /> Swedlund Septic Service is submitting the enclosed individual sewage <br /> treatment system design for the above referenced site, along with the results <br /> of the site evaluation (soil borings & perc tests). <br /> The soils at the site consist of ��'" . Standing water was <br /> not encountered in any of the soil borings, but mottling associated with <br /> seasonal saturation (wet soils) was found as shallow as zZinches below <br /> grade surface and as deep as 3�inches below grade surface. This indicates <br /> that a standard trench system is not suitable for the site. The perc test results <br /> ( /G Mi°� ) indicate that the soils are suitable for treatment using a mound <br /> system. <br /> The home is an existin� S bedroom home. A standard mound <br /> system with 1�{ inches of clean washed sand below the distribution rock <br /> should be suitable as a new system for the site. We recommend a flow of <br /> 7�S"O gallons per day for use in design, and azzso gallon septic tank <br /> andiz.so gallon pumping tank. THIS SYSTEM MUST BE INSTALLED <br /> BY A LICENSED INSTALLER IN ACCORDANCE WITH CHAPTER <br /> 7080. : <br /> Swedlund Septic Service • 9520 Laketown Road • Chaska, MIv 55318 • 442-5855 <br /> STATE CERTIFIED <br />