Laserfiche WebLink
. � ,�. ��f <br /> PAI.o }'�� ����.� ������� <br /> � Companies, Inc. <br /> May 19. 2003 Quotation: Q 16�2ah <br /> Greg Carlson <br /> Orono, MN <br /> This quote is fo� labor and materials to instail the following heating, ventilation, and air <br /> conditioning (FiVAC)system in yaur new home in Qrono: <br /> 9. Furnaoes are by Coleman, model G9T080i6UPC, (80,000 Btu, sealed combusti.�n, <br /> 94°lo AFUE, gas furnace with 4-ton blower) <br /> 2. Air conditianer, first floor, is by Coleman, model FRCSO42. (3.5-ton, 14 SEER with <br /> R-22 refrigerant) <br /> 3. Air canditfoner, second fioor, is by Coleman, model FRCS030. (2.5-ton, 14 S�ER <br /> with R-22 refngerant) <br /> 4. Air exchanger is by Venmar(VanEE), model HE2.6. (265 cfm, high efficiency he,at <br /> recovery ventilator) <br /> 5. Humidi�er is by Aprllaire, model 560. (Bypass type. 17 gaUday) <br /> 6. Thermostat is by Honeywell(full 7-day programmable with two-stage heat, two-stage <br /> cool, with sepafate hurhidity control) <br /> 7. Fumace filter is EZ-Flex. (MERV 10, expandable media filier) <br /> 8. Supply air ducting is a11 sheetmetal, with limited flex duct. Ducting will be installed in <br /> second floor attic and at basement ceiling. <br /> 9. Return ei�ducting will be routed as needed. <br /> 10. HRV duct will start in the mechanical room gnd sourcepoint to powde�bathroom and <br /> laundry. Bathroom wall timer for HRV wfl( be supplied for installation by the <br /> �lectrician. <br /> 11. Dryer and range venting will be instsHed as r�equired. <br /> 12. Copper gas piping will be installed from outside to mechanical room gas manifold. <br /> To supply fumace, fireplace bcation, wat�r heater and dryer. <br /> TOTAL: �16,SS2.00 <br /> Options: <br /> Radiant lloor system with electric boiler, controls,Wirsbo iubinp, insuletion for <br /> basement. AD�� $5,258.00 <br /> Radiant floor system without boiler or controls ADD: $3.316.00 <br /> Garage unit heater with venting and gas piping ADD $1,112.00 <br /> Class"A"chimney from basement fireplece location thru roof ADD $1,705.OU <br /> Point of interest: <br /> • I chose not to include installation of the gas fireplace with the base quote. I <br /> thought that it may be more appropriate if the supplier oi the fireplaces install <br /> them (I do have gas piping included from the mechanical roam) <br /> Assumes: <br /> 7hete will be a second floor mechartical room <br /> Second floor duciing will be run in the attic <br /> Second floor bathrooms will have exhaust fans provided by electrician and w�ll nc�t be <br /> cvnnected to the air exchanger. <br /> There are no hidden beams in the first floor <br /> 14208 U,S.HIQHWAY 12 SOUTNWEST•COKATO,MINN6SOTA 65321 <br /> 320-286-6133•FAX 320-296-3230 <br />