Laserfiche WebLink
, � <br /> WETLAND <br /> \ DRAINAGE LEGEND <br /> EASEMENT <br /> �— —� — — — --�_ � � denotes well location <br /> / �5't �8�` �- � � G denotes perc test locatron <br /> � � denotes soil boring location <br /> � � �'' �, � 1 ( 97*8 ) denotes proposed elev. <br /> � � 97*8 denotes existing elev. <br /> � se5� sBs � -�-- denotes surface drainage <br /> / � �� I D <br /> /22.2� FS�\ I Z <br /> I � <br /> � <br /> � ���2 �21' �°^o Se� 'pc�`,�68� I I APPROXIMATE PRIMARY MOUND QUANTITIES <br /> �� �� 20.9� � 'i 25't Rock Quan fity — 23.3f yards <br /> / � s , <br /> � ,, � Sand Quantity = 220t yds. <br /> J� � 13 8, 1300 GALLON LI�'T � Loamy Sand Quantity = 18f yds. <br /> EXISTING � � ,( ` TANK I <br /> DEEP WELL � � � ' \98 S81 �Sg I Top Soi/ Quantity = 90f yds. <br /> \ \ � / � \ SB3 ` I I *Quanfrties are approximate <br /> \ � c��' � �8 � ` � and do not include waste <br /> '\ � \ �2 / 8\ \ ��2 \ �o �8�--� I � <br /> \ \ \o � <br /> 5 \ � \ � �\ / s� \ 2�300 GA\ N \ — — �28 I <br /> � \ \ \ � SEPTIC TANKS� \ I � <br /> � / ��' � � \ � -� — —�8 �_ — — .___ _ <br /> � \ � � / \ � � � � \ ( — <br /> \ � �" � � I NOTE: SEPTIC SITES ARE TO BE ROPED OR FENCED <br /> � � � ��5 �98-� ��" -- OFF TO PREVENT UNWANTED DISTURBENCE. FENCEING <br /> �s BENCH ARK: OP Nq � '' -- SHOULD BE LEFT UP THROUGH—OUT THE <br /> � � �RNER OF EL�CTRICA� � p � � ` � CONSTRUCTION PROJECT. <br /> \ B \ ELEVc=100.Q (ASS�MED) � J Cy�R pSF� \ ��97*OJ\ -.� � <br /> � \ � �\ � � '��, 3 ��S eeoRo \��\ <br /> � � � \ � a � � �M� <br /> \ � / �6 <br /> � \ \\ \�+ � � \ �9�*� <br /> � � �6� � � <br /> \ / Notes <br /> � � Q <br /> � � � PROPOSED 1. Avoid compaction of mound area before, during and after <br /> � \ � � � � � 9c�� DEEP WELL construction. <br /> \ � � � � 50' 2. Verify before construction that no wells are within 50 feet <br /> �Q�C, � � \ � of the proposed or existing septic tank. <br /> \ aS \ \ � / <br /> / 3. Verify before construction that no shailow welis are within 100 feet, <br /> \ �2 � \� / / or any deep wells within 50 feet of proposed treatment area. <br /> \ll \ � �� / 4. All materials used for construction must meet or exceed the <br /> �\ � M.P.C.A. Chapter 7080 requirements. <br /> ��4Q. \ _ f � � 5. Divert surface drainage away or around the septic area. <br /> � � - - - 6. Ail dimensions, quantities and elevation shown on plan are approximate. <br /> � <br /> 8g� 6� J <br /> MlLLER'S SEW4GE TREATMENT SOLUTIONS PROPERTY LOCATION PREPARED FOR: I hereby certify that this site plan was prepared by me or <br /> A division of WRM Services /nc. LOT 4, BLOCK 1, JACOBS MIIL, Septic System Site Plan Robert Fitch Const. under my direct superv' ion. <br /> HENNEP�N COUNTY, MINNESOTA. <br /> PO BOX 458 Kimball, MN 55353 (3670 JACOB MILL ROAD) DATE JOB N0. SCALE IVan Slooten Res.� ,��,�'��' <br /> (320) 398-2705 ceil (320) 980-1737 7/2$/�4 ��4'14 i�g� iller 0. .P. M. P. G A. License 1921 <br />