My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-00784 - septic
Orono
>
Property Files
>
Street Address
>
J
>
Jacobs Mill Road
>
3625 Jacobs Mill Road - 32-118-23-24-0013
>
Septic
>
2013-00784 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:40:20 PM
Creation date
3/14/2017 1:54:27 PM
Metadata
Fields
Template:
x Address Old
House Number
3625
Street Name
Jacobs Mill
Street Type
Road
Address
3625 Jacobs Mill Road
Document Type
Septic
PIN
3211823240013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purplecode Mound Design <br /> www.SepticResource.com (vers 12.6) <br /> Property Owner: Kurt Carol Schmidt Date: 5/16/2013 <br /> Site Address: Jacob Mill Road Orono MN 55364 P1D: <br /> Comments: <br /> instructions: � =site specific input � =adjust if desired � =self-calculated {DO N07 ADJUST) <br /> �� ��4 bedroom Type �I Residential System <br /> 2) �GPD design flow <br />` 3) No Garbage disposat or pumped to septic <br /> ) 1500 Gal Septic tank(code minimum} 2000 Gat Septic tank (design size / LUG req'd) <br /> Tank options: Multipte tanks or campartment reqd <br /> s) 1.2 GPD/ftz mound sand loading rate <br /> 6� 90 ft rockbed width 50.0 ft rockbed length <br /> � 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifotd connection <br /> s) �3 laterals 48.0 feet long 17.0 perfs / tateral 51 perfs total <br /> (1/2 a perf ineans the first perf starts at the middle feed manifotd► <br /> . 9? 1/4" inch perfs at �1 feet residual head gives 0.74 gpm flow rate per perforation <br /> for this perf size ft spacing, �t pipe size on line 12, max perfs/lateral= 25 , line#8 must be less--> OK <br /> to) 4.Q doses per day (4 minimum) <br /> ii� 150 gallons per dose (treatment volume) <br /> i2� 2,00 inch diameter laterals (or smalter)will meet"5x pipe volume" <br /> 2.00 inch diameter lateraLs (or smaller) must be used to meet"4x pipe volume"reguirement <br /> 2.00 inch diameter laterats (or smaUe�j will meet"3x pipe volume" <br /> ts� 30 feet of 2.0 inch supply line leads ta �5 gallons of drainbatk votume <br /> (Tip: "top feed"manifoid to cantrot the drainback) <br /> �a� 155 �allons TOTAL pump out volume (treatment+drainback) <br /> ts� 8 feet verticat lift from pump to dispersal area, leads to a: <br /> �6� 38 GPM� 15 feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> i�> 500 gal Dose tank(code minimum) 1000 gal Dose tank(design size / LUG reqd) at 25.00 gpi <br /> teads to a <br /> is� 6.2 inch swing on Demand itoat, or timed dosing of 4.1 min ON (confirm pump rate with drawdown <br /> (to detiver Average flow, 66%of Peak design flow) 9 hrs OFF test and adjust as necessary} <br /> �9� 12 inches from bottom of tank to"Pump OFF"float <br /> ao) 18 inches from bottom of tar�k to"Pump ON"float, or 12 mches to'Timer ON"float if time dosed <br /> 2t> 21 inches from bottom of tank to"Hi Level"float, or 31 inches to"Hi level"float if time dosed <br /> 22� 475 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.