<br /> $�RI,�'�Uth11131'�(�b3t7S ,� >
<br /> Component Area Sen. Lat. Sen. Totai
<br /> Description Quan Loss Gain Gain Gain
<br /> 3D Window Doubie Pane Low Emit Wood Frame 624 20,724 0 29,970 29,970
<br /> 11E Door Metal Urethane Core 42 734 0 188 188
<br /> 12H Wall R-19+1/2"Gypsum Board(R-0.5) 2,147 11,853 0 3,040 3,040
<br /> 15G Wall 5'or More Below Grade 8112"BIk+R-11 873 3,454 0 0 0
<br /> 161 Ceiling R�4 Insulation 2,196 4,647 0 2,222 2,222
<br /> 21A Basemt Floor 2'or More Below Grade 2,196 4,849 0 0 0
<br /> Subtotals for sUucture: 8,078 46,261 0 35,420 35,420
<br /> Active People: 4 0 920 1,200 2,120
<br /> Inactive People: 0 0 0 0 0
<br /> Appiiances: 0 0 0 0 0
<br /> Lighting: 0 0 0 0 0
<br /> Ductwork: 0 13,349 0 7,621 7,621
<br /> Infiltration:Winter CFM:208.6,Summer CFM:69.5 666 20,484 1,652 1,484 3,136
<br /> Ventilafion:Winter CFM:69.5,Summer CFM:69.5 0 6,828 1,651 1,484 3,136
<br /> Sensible Gain Total: 47,209
<br /> Temperature Swing Multiplier: X1.00
<br /> System Load Totals: 86,922 4,223 47,209 51,433
<br /> � �ril., ..� .� :. y �Y' , �! � kk ��qr ��1��'if�t`�i� �t f ..
<br /> A1 s� ��� .m �,.�- .�3 ,�` .�� �f �� ,�e�-tRrt,�',-��-��� _�
<br /> Supply CFM: 2,142 CFM per square foot: 0.488
<br /> Square feet of room area: 4,392 Square feet per ton: 859.62
<br /> ���„{ ° ��
<br /> �_� �
<br /> Total heabng requi�ed with outside air. 86,922 Btuh 86.922 MBH
<br /> Total sensible gain: 47,209 Btuh 92 �o
<br /> Total latent gain: 4,223 Btuh 8 %
<br /> Total cooling required with outside air. 51,433 Btuh 4.286 Tons(based on sensible+latent)
<br /> 5.109 Tons(based on 77%sensible capacity)
<br /> r�;:� �-� ..0� '
<br /> �< �
<br /> Calculations a�e based on 7th edition of ACCA Manual J.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads.
<br /> � Friday,May 26,2000