GENERAL NOTES: <br /> 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF <br /> 2250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE SUPPORTED BY THE FINAL INSTALLED <br /> FLOOR CONSTRUCTION AT BOTH THE TOP AND BOTTOM, UNLESS ADEC�UATE SHORING IS INSTALLED AS REQUIRED. <br /> SHORING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. <br /> 2. STRIP FOOTINGS MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. <br /> 3. 1y"DEEP BY 3y"WIDE BY CONTINUOUS KEYWAYS, LOCATED ANYWHERE WITHIN THE WALL WIDTH, MAY BE USED IN <br /> LIEU OF DOWELS FOR FULL HEIGHT AND FROST WALLS. <br /> 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 1". A MlNIMUM OF 2"OF STRIP�FOOTING IS TO <br /> EXTEND BEYOND THE WALL FACE EACH SIDE. <br /> 5. PROViDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTIN�S. <br /> 6. SLOPE GRADE DOWNWARD AWAY FROM THE STAUCTURE A M�NIMUM OF 6"WITHIN THE FIRST TEN FEET UNLESS <br /> ADEQUATE DRAINS OR SWALES ARE PROVIDEQ. <br /> 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE,WATER-PROOFING,CONTROL JOINTS, FLASHING,AND <br /> INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTFD <br /> OTHERWISE. <br /> 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS,UNLESS NOTED OTHERWISE. <br /> 9. REINFORCING PLACEMENT TOLERANCE IS 1/2". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. <br /> MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 <br /> STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. <br /> 10. PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. <br /> HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL WIDTH AS LONG AS A MINIMUM OF 2"OF CLEAR <br /> COVER iS PROVIDED. <br /> 11. REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE 6ARS: <br /> 12. DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. <br /> VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. <br /> 13: THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF FORM OIL IS PRESENT <br /> FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. <br /> 14. SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO <br /> HAVE AN ANCHOR WITHIN 4"TO 12"OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND <br /> INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A <br /> MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE <br /> REQUIREMENTS. <br /> t5. SILL PLATES ARE NOT REQUIRED TO BE TREATED IN ACCORDANCE WITH IRC SECTION R319.1 ITEM 2. ANCHOR <br /> BOLTS 1/2"OR LARGER IN DIAMETER ARE NOT RE(�UIRED TO BE CORROSION PROTECTED IN ACCORDANCE WITH IRC <br /> SECTION R319.3 EXCEPTION 1. <br /> 16. ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE <br /> MANUFACTURER'S REOUIREMENTS. <br /> Rev Date 2008 MASTER C.I.P. CONCRETE SITE ADDRESS: <br /> FOUNDATION DRAWINGS <br /> GENERALNOTES <br /> CLIENT INFORMATION: City: State: Zip: " � <br /> SITE SOIL TYPE: — <br /> CHARLES CUDD, LLC SAND❑ SANDY CLAY� CLAY� <br /> 275 MARKET STREET, SUITE 445 520i Eas�RiverPd <br /> Suite 308 <br /> MINNEAPOLIS, MN 55405 Project Number: 207.1200 A Minneapolis,MN55421 <br /> � Drawing Date: 01-01-08 �,� Te1763-577-2500 <br /> Fhone: 6i1-3;�3-8u2u Fax: bi2-335-5�i7i F��;s,-�;,.;�ss <br /> She2t: 3 Of 18 � www.ultelg.com <br /> �O COPYRIGHT ULTEIG ENGINEERS INC.2008 <br />