<br /> Component Rrea Sen. Lat. Sen. Total
<br /> Description Quan Loss Gain Gain Gain
<br /> 3A Window Double Pane Clear Glasa Wood Frame 743 36,846 0 16,772 16,772
<br /> 10G Door Wood Panel 21 1,266 0 332 332
<br /> 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 3,508 18,94� 0 4,966 4,9�6
<br /> 15B Wall 2-5'�elow Grade$/12"B)k*R-5 150 899 0 0 0
<br /> 16H Ceiling R-38 Insulation 1,699 3,975 0 1,544 1,944
<br /> 21A Basemt Floor 2'or More Below Grade 1,701 3,674 0 0 0
<br /> Subtotals for structure: 7,822 65,703 0 24,014 24,014
<br /> Active People: 0 0 0 0 0
<br /> Inaeti�re Peopie: 0 0 0 0 0
<br /> Appliances: U 0 0 U 0
<br /> Lighf�ng: 0 0 0 0 U
<br /> Ductwork: 0 8,762 U 2,726 2,726
<br /> Infittration:Winter CFM:228.0,Summer CFM: 152.0 764 21,906 1,797 3,2�6 5,043
<br /> Ventilation:Winter CFM: 10Q.0 Summ�r CFM: 140.0 0 9,608 1,183 2,135 3,318
<br /> Sensible Gain Total: 32,121
<br />. Temperature�wing MutUpBer X1.00
<br /> Buiiding Load Totals: 105,98 2,880 32,121 35,1v7
<br /> � • 0
<br /> , , ,;
<br /> .
<br /> ., ; .
<br /> ��
<br /> :� �-. .. �.�. . _ m ,... ,��,�.��. , . ,.. n:
<br /> �
<br /> T�tal Buildin9 SuPply��M: 1541 �FM psr sq�ere fQQt: 0.325
<br /> Square feet af room area: 5,041 Square feet per ton: 1,374.757
<br /> x.
<br /> Total hea�ng required witl�outside air: 105,980 Btuh 105.980 MBH
<br /> Total sensible gain: 32,121 Btuh 9� �!o
<br /> Tota�latent gain: 2,980 �tuh 8 '/'e
<br /> Total cooling required vvith outsid�air: 35,101 Btuh 2.925 Tons(bas�d on sensible+I,at�nt)
<br /> 3.667 Tons(based on 73%sensible capacity)
<br /> k. . . .r . ..�.. .. . .: . . � � i '
<br /> R
<br /> ��I��ledqns�rs b���d on 7th edi��n of A�CA Manual J.
<br /> All computed results are estimates as building use and weather may vary.
<br /> B�sure to select a unit that meets both sen�ible and latent loads.
<br /> Tuesday,February 29,2000