i O—� ,
<br /> 7 , � �. ,
<br /> ..,.:. .. ;' �•.. ..,;,_�... .:: . ,,,. _ , ',.�. . . r:.,
<br /> - ._�.: � � �.o.,.".,, _ '"- rs�� - .aa�:_....
<br /> ,,� 0 ��`�, _
<br /> `� ���� � '` CITYof URONU
<br /> ..�;r.
<br /> ��+, `�f���. ;a�`� ,. . ti Municipa� ot�ces
<br /> , ,� �;-;.,�,�. , � . ., ti,
<br /> � ����..���¢`' G street aaaress: qsa-a49-'i6o 0
<br /> � ,. , � � Mailing Address:
<br /> `9$EggOg' 2750 Kelley Parlcway � P.O. Box 66
<br /> Orono, MN 55356 Crystal Bay, MN 55323•0066
<br /> To Current Owner: Address: �a� �U��l p"-'S�
<br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
<br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
<br /> STEM CONFORMITY 1-3 : �
<br /> 1 "CODE SYS1'EM"An ISTS which meets all the 1ocation,design and construction standazds of the current Orono Municipal Code.
<br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
<br /> Municipal Code but does meet the thr�foot separation requirement or two foot requ'uement for systems installed 1996 or earlier,and
<br /> which is not failiag or an i�inent threat to public health or safery.
<br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a dcsignated 100-year flood plain,any ISTS which may
<br /> or may not�et all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failiag for any
<br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limitiag soil characteristics.
<br /> TANK CONDI'I'ION(5-71: �
<br /> Tank inspeetion indicates: _
<br /> ` 5 Pumpout not needed at this time.
<br /> � Septic tanks must be pumped out this year{city code recommends tanks to be pumped out once every 3 years.
<br /> Tank was last pumped_ ).
<br /> Make sure seotic tanks are aumaed throu¢h manhole and not throu¢h white insoection ui�es This aliows for the aroaer
<br /> cleanin¢. Keea water softner and iron filter dischar¢e out of seotic svstem to prolon¢life of drainfield Ask uumoer to test
<br /> alarm float to verifv alarm is still workine in vour house The slarm warns owner that seataee is about to backuo into basement
<br /> 7 Inspectaon risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)xnust be installed in each tank. If
<br /> tanks have not been pumped out within the last three years,they should be pumped out now.
<br /> DRAINFIELD CONDITION(8-10): ,� . .. . _
<br /> UDrainfield is dry,no surfacing evident.
<br /> 9 Some evidence of surfacing,not critical yet. -
<br /> 10 Drainfield is saturated and visibly discharging untreated ef�luent to the surface. Contact the City Inspector
<br /> immediately.Repairs must be completed within 90 days. -
<br />. __ , l``D v� �.
<br /> COMMENTS: ...,.._... tlbl(� _ �1(._. ,. �,'U�„�� �'o i+�{.�
<br /> -�- � �':��:fr1_ , .
<br /> :f� QU nr� 't'e�c�,�.l
<br /> ��1�-o� G�.,� �,,�
<br /> Date of Tnspection Matt Bolterman - Septic System tnspector
<br /> Note: in the event that this inspection report is used to satisf'y the requirements for a mortgage or other transfer of property, be advised that this_repon does
<br /> not guarantee or certify that an e�isting system �vill continue to function properl�•. but is merely an opinion of the adequacy of the spsrem under current
<br /> cunditions based on the evailable inlortnation.
<br />
|