My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
H
>
Hunter Drive
>
1070 Hunter Drive - 25-118-23-42-0008 (Formeraly 300 Sixth Ave N)
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:17 PM
Creation date
3/1/2017 1:08:01 PM
Metadata
Fields
Template:
x Address Old
House Number
1070
Street Name
Hunter
Street Type
Drive
Address
1070 Hunter Drive
Document Type
Septic
PIN
2511823420008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I 1� <br /> \ . � <br /> M���es������ OSTP Design Summary Worksheet UNIVERSITY <br /> Conuol Agency OF MINNESOTA �.r <br /> Mound Design Summary <br /> Absorption Bed Area 630.0 ft2 Bed Length 63.0 ft Bed Width 10.0 ft <br /> Absorption Width 26.0 ft Clean Sand Lift �,g ft Berm Width (0-1�)�ft <br /> Upslope Berm Width g,5 ft Downslope Berm Width 23,7 ft Endslope Berm Width �3,p ft <br /> TotalSystem Length g9,p ft TotalSystem Width 43.3 ft Contour Loading Rate 12.0 gal/ft <br /> At-Grade Design Summary <br /> Absorpt9on Bed Width�ft Absorption Bed Length�ft System Height�ft <br /> Contour Loading Rate�gal/ft Upslope Berm Width��ft Downslope Berm Width�ft <br /> Endstope Berm Width�ft System Length��ft System Width�ft <br /> Level Ft Equai Pressure Distributton Summary <br /> No.of Pertorated Laterals� Perforation Spacing�ft Perforation Diameter��� <br /> Lateral Diameter�in Min. Delivered Volume�ga� Maximum Delivered Volume�gal <br /> Non-Level and Unequal Pressure Distribution Summary <br /> Elevation Pipe Votume Pipe Length Perforation Size <br /> (ft) Pipe Size(in) (gal/ft) (ft) (in) Spacing(ft) Spacing(in) <br /> Lateral 1 Minimum Delivered Volume <br /> Lateral 2 <br /> Lateral 3 gal <br /> Lateral 4 Maximum Delivered Volume <br /> Lateral 5 <br /> gal <br /> Lateral 6 <br /> 5, Additional Info for Type IV/Pretreatment Design <br /> A. Calculate the organic loading <br /> 1. Orgon�c Looding to Pretreatment Unit =Design F(ow X Estimated BOD in mg/L in the effluent X 8.35 t 1,000,000 <br /> 4Pd X ��mg/L X 8.35-r 1,000,000- �_��bs BOD/day <br /> 2. Type of Pretreatment Unit Being Installed: <br /> 3. Calculate Soil Treotment System Organic Loading: BOD concentration after pretreatment�Bottom Area =lbs/day/ftZ <br /> mg/L X 8.35+1,000,000 � C�{�2= �lbs/day/ft2 <br /> Comments/Special Design Considerations: <br /> I hereby certify that I have completed this work in ac dance with all applicable ordinances,rules and laws. <br /> Joseph J Olson 810 04/08/16 <br /> (Designer) �¢' (Signature) (License#) <br /> (Date) <br />
The URL can be used to link to this page
Your browser does not support the video tag.