Laserfiche WebLink
On the Nortb Sbore o f <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> � . � � 1335 S. Brown Rd. <br /> Crystal Bay,MN 55323 <br /> � 473-7357 <br /> OWNER � �"� ��►'/ AODRESS �'�"S �h��Ari�'1 �A, <br /> PERMIT NO.'S. ���-3 DATES /'��`�� CONTRACTORS L��'J�-°r n�_/l � <br /> City Ordinsnce No.210 requires that each on-aite sevrage treatment system in Orono be inspected on a regular basis.The onsite sewa� <br /> trestment syatem at the above address haa been inspected and sppesro to fall into the category checked below. <br /> (This is � en existing syatem ❑ new conatructionl <br /> � � Meets or excseds current City standards in all respects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> � 2 Does not meet all current City stenderds for new construction (1978 Code) but in most respects appears to be designed, <br /> loceted, and constructed generally in accordence with previous codes.System appears to be functioning properiy;no major <br /> upgreding of the systern is required at this time. <br /> � 3 Does not meet current City standards in many respects relating to desig�,construction,or location.Appears to be operating <br /> adequately at this time,but has a�elatively high potential for future problema. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and <br /> dispose of the current input,and is endangering a water supply,or ia a source of poliution to surface or groundwaters,or is <br /> creating a ssfety hazard,or is otMerwiae creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replecement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your cont�actor must obtain a permit before work is atarted. <br /> SYSTEM CONDITION (m Checked items may require your action) <br /> Tank inspection indicatea: ❑ Inapection pipe is located directly ove�tank baffle.(Does not <br /> �Pumpout not needed at this time, give accurate me�uremeet of solids aceumulation.l If tanks <br /> Solids accumulation in te�ks indicates they ahould be pump� have not been pumped out within the last three yean,they <br /> ed out this year to help provent future problema. should be pumped out�ow. <br /> ❑ Solids accumuletion in tanks ia at a critical level. Tanks Drainfield inapection indicates: <br /> ahould be pumped out�aoon as poasible. � Drainfieid ia dry,no surfacing evident. <br /> ❑ System is diacharging to surface. Tenks must be pumped 0 Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate aurface discharge. ❑ Drainfield is saturated and visibly discharging untreated <br /> ❑ Inspection risers missing—tanks could not be inapected. effluent to the surf�e. This condition may require replace- <br /> inspection risers (4"dia.pipe)must be instelled in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tank�have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they ahould be pumped out now. ❑ Drainfield extent and condition u�know�. <br /> SITE CHARACTERISTICS <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> O Soil table,and system conditio�) �Adequate <br /> ❑ High water table �Low ❑ Fair <br /> ❑ Lot size O Medium O Poor <br /> ❑ Lake,wetland,or stream ❑ High . O Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surfac�diacF►arge. <br /> COMMENTS: <br /> 9/�90 <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function pro�rly,but is merely an opinion of the adequacy <br /> of the system under current conditio�s besed on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeow�er <br />