My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00081 - septic
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Trail
>
100 Bayside Trail - 06-117-23-22-0026
>
Septic
>
2017-00081 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:05 PM
Creation date
3/1/2017 8:17:24 AM
Metadata
Fields
Template:
x Address Old
House Number
100
Street Name
Bayside
Street Type
Trail
Address
100 Bayside Tr
Document Type
Septic
PIN
0611723220026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2000 gallon Septic tank(minimum) Tank options: none <br /> �u�iarger tanK wi�n muiupie cornpi�anKs <br /> 1000 gallon Dose tank (minimum) at 25.00 gpi <br /> 29 GPM C� 17 ft. of head, Pump required <br /> 5.3 inch swing on Demand float which translates to roughly 3.7 inches of float tether length <br /> if time dosing is required--> 4.6 minutes ON time�C �9 hours OFF time <br /> 17 inches from bottom of tank to"pump ON"ftoat,or 12 inches to"timer ON"float <br /> 20 inches from bottom of tank to"Hi level Alarm"or 30 inches to"Hi tevel alarm"if time dosed <br /> 120 ft. of 2.0 inch supply line with end feed manifold connection <br /> (Tip: "top feed"manifotd to control drainback) <br /> 16 inch, or 1.3 ft. Sand Lift Mound <br /> 10.0 ft. wide by 38.0 ft. long Rock bed <br /> 3 laterats 2.00 inch diameter 36.0 ft. long 3.0 ft. lateral spacing <br /> 1/4" inch perfs 3.0 ft. perforation spacing <br /> No Efftuent filter&alarm <br /> 3 clean out ft vatve box assembties <br /> 20.0 ft.Total sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br /> 10.0 ft. Downslope (sand beyond rockbed, minimum) <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed)of: <br /> 4:1 upslope ratio 90 ft. upslope berm <br /> 3:1 sideslope 12 ft. sideslope berms <br /> 3:1 downslope 20 ft. downslope berm <br /> 4" inspection pipe <br /> 18" cover on top <br /> U sl berm �� Downsto berm 20 <br /> 12" cover an sides <br /> ce°��y��&6u to�o� <br /> 1.3 Clean sand lift <br /> , �.7 ��C� Yiy iifi`1ii11,�,� <br /> Liir�rtin� Condition_� _ __._..____�___.`� <br /> Absor tion Width 20.0 -""i_-_--_ _-______�_. <br /> Note• <br /> For 0 to 1�6 slopes, Abso�ption Width is measured from the Bedequalty in both directions. <br /> For slopes >1�, Abso�ptia�r Wldth is measured downhili from the upslope edge of the 8ed. <br /> Rock Bed: 13.0 yd3 or*1.4= 18 ton 6 inches under pipe <br /> Mound Sand: 110 yd3 or"1.4= 155 ton catculation based on 3:1/4:1 slope from top of rockbe� <br /> Loamy Cap: 47 yd3 or'1.4= 66 ton 6"deep <br /> Topsoit: 56 yd3 or;1.4= 78 ton 6"deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.