Laserfiche WebLink
� °� <br /> 0 0 _ <br /> .�=�;� � _ CITY o� ORONO <br /> r3 'r�g�,j.�`�. `: � _ <br /> . <br /> ' F►. <br /> � Municipal Offices <br /> '�\� ��P.� �f y� '., . . <br /> ��'•. <br /> :����, <br /> � � �-�t�;:�� :..� G,y// <br /> ��� ,;- �{j...� ;, Street Address: �15a-a4q-�6o � Mailing Address: ' <br /> \���,� �.� .¢,'��,- <br /> ,..\�5��� 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: �Ct�C7 f-��too--T 1--s�t/� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYST'EM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM"An ISTS which meets all the locarion,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cuaent Orono <br /> Municipal Code but does meet the three foot sepazation requirement or rivo foot requ'uement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and ihe luniting soil characteristics. <br /> TANK CONDITION(5-7): �7 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped i�{��, ). <br /> Make sure seatic tanks are aumaed throush manhole and not throueh white insaection aiaes. This allows for the arouer <br /> cleanina. Keea water softner and iron filter discharee out of seatic svstem to orolons life of draintield. Ask numper to test <br /> alarm float to verifv alarm is still working in vour house. The alarm warns owner that septaee is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> �;� - �2 _� � C�� (� <br /> Date of Inspection Septic System Inspector <br />