Laserfiche WebLink
� °� <br /> 0 0 <br /> ;r%��,,r�,_ _ � CITY of URONU <br /> � ��,� ���: <br /> *� � � �ti Municipal Oftices <br /> ,\\ ��t.''. 'r.�;; '�j:r � . <br /> �` � !�� ;-�� ;��" G� SVeet Address: °15a-a49'�160 � Mailing Address: <br /> �`�,� -.�.�.;�� 4,� � <br /> ., k�Hp � 2750 Kelley Parkway P.O. Box 66 <br /> �_ -�' Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: ��5� Nc�/►'iP S 1`�!� ci T/�• <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> �,CYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM"An LSTS which meets all the location,design and construction standazds of the current Orono Municigal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requuement for systems installed 1996 or earlier,and <br /> which is not failing or an i�inent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or conshucdon standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characterisdcs. <br /> TANK CONDITION(5-7): S <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure seatic tanks are aumaed throush manhole and not throu¢h white inspection aiaes. This allows for the aroaer <br /> cleanins. Keea water softner and iron 51ter discharge out of seatic svstem to urolons life of drainfield. Ask aumaer to test <br /> alarm float to verifv alarm is still workin¢in vour 6ouse. The alarm warns owner that seatase is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly dischazging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: A..i a �lJ. ,;,a „ -t � ,1,�.� s r <br /> io <br /> �-� � .�� (.��- <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not euarantee or certifv that an existinQ Svstem will continue to function properly, but is merely an opinion of the adequacy of the system under current <br />