x Address Old
House Number
1150
Street Name
Homestead
Street Type
Trail
Address
1150 Homestead Trail
Document Type
Septic
PIN
2811823320018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2250 gallon Septic tank (minimum) Tank options: none <br /> 750 gallon Dose tank (minimum) at 26.00 gpi <br /> 47 GPM @ 21 ft. of head, Pump required <br /> 7J inch swing on Demand float which translates to roughly 4.9 inches of float tether length <br /> if time dosing is required --> 4.3 minutes ON time tt �hours OFF time <br /> 20 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float <br /> 23 inches from bottom of tank to"Hi Level Alarm"or 33 inches to"Hi level alarm"if time dosed <br /> 75 ft. of 2.0 inch supply line with end feed manifold connection <br /> (Tip: "top feed"manifold to controt drainback) <br /> 12 inch, or 1.0 ft. Sand Lift Mound <br /> 10.0 ft. wide by 62.5 ft. long Rock bed <br /> 3 laterals 2.00 inch diameter 60.5 ft. lonq 3.0 ft. lateral spacing <br /> 1/4" inch perfs 3.0 ft. perforation spacing <br /> No Efftuent filter&t alarm <br /> 3 clean out&valve box assemblies <br /> 20.0 ft.Total sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sidestope (sand beyond rockbed, minimum) <br /> 10.0 ft. Downslope (sand beyond rockbed, minimum) <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br /> 4:1 upslope ratio 11 ft. upslope berm <br /> 4:1 sideslope 13 ft. sideslope berms <br /> 4:1 downslope 15 ft. downslope berm <br /> 4"inspection pipe <br /> 'i 8" c�ov�er vn t�p <br /> U lo berm �� Qawnsla e berm �5 <br /> 1 Z" cover on sides <br /> {6"loamy cap&6"topsoil} <br /> 1.0 Glean sand laft <br /> _ 2�0 De�th to Limitin� <br /> �_.�_�..___. <br /> L.irt�i�in "' ' <br /> � Cc�nditican --,..�._�-.__.�...._ <br /> Absar tiun Wicith 20.o —"��_� �- —-�_ �._�_�_ <br /> Note: <br /> For 0 to 1�slopes, Absorpt�'on W�dth as measur+ed #rom th�e Bedequally in both dir�ections.. <br /> For slopes >9�6, �1Gsrarptlo,� M�+'dth is measured downl�ill fram t�e upstope etl�e of the Ba�d. <br /> Rock Bed: 21.0 yd3 or"1.4= 29 ton 6 inches under pipe <br /> Mound Sand: 110 yd3 or"1.4= 154 ton calculation based on 3:1/4:1 slope from top of rockbe� <br /> Loamy Cap: 61 yd3 or"1.4= 85 ton 6"deep <br /> Topsoil: 71 yd3 or*1.4= 99 ton 6"deep <br />