2016-00773 - new septic
Orono
>
Property Files
>
Street Address
>
H
>
Homestead Trail
>
1150 Homestead Trail - 28-118-23-32-0018 - New PID
>
Septic
>
2016-00773 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:17 PM
Creation date
2/27/2017 2:10:44 PM
Metadata
Fields
Template:
x Address Old
House Number
1150
Street Name
Homestead
Street Type
Trail
Address
1150 Homestead Trail
Document Type
Septic
PIN
2811823320018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purplecode Mound Design <br /> www.SepticResource.com (vers 15:2) <br /> Property Owner: Dave Mariani Date: 5/5/2016 <br /> Site Address: 1150 Homestead Trail Orono, MN PID: 28-118-23�32-0018 <br /> Comments: type 1 5 bedroom mound <br /> instructions: � =enter data � =adjust if desired � = computer calculated - DO NOT CHANGEI <br /> i> �bedroom Type � Residential System <br /> z) 750 GPD design flow <br /> 3) �Garbage disposal or pumped to septic <br /> a� 1500 Gal Septic tank(code minimum) 2?50 Gal Septic tank (design size / LUG req'd) <br /> Tank options: none <br /> s> '1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br /> 6> 10:0 ft rockbed width 62.5 ft rockbed length <br /> �) 3.0 ft lateral spacing 3.0 , ft perforation spacing (maximum of 3 for both) <br /> �nd feed manifold connection <br /> 8) �3 laterals 60.5 feet long 21.0 perfs / laterat 63 perts total <br /> (1/2 a perf ineans the first perf starts at the middle feed manifold) <br /> 9� 1/4" inch perfs at �feet residual head gives OJ4 gpm ftow rate per pertoration <br /> for this perf size&spacing, £t pipe size on line 12, max perfs/lateral= 25 , line#8 must be less --> OK <br /> io� 4.0 doses per day (4 minimum) <br /> i�� 188 gallons per dose (treatment volume) <br /> 2.00 5x <br /> i2� 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> is� �feet of 2.0 inch supply line leads to 13 gatlons of drainback volume <br /> (Tip: "top feed"manifotd to control the drainback) <br /> ia� 201 gallons TOTAL pump out volume (treatment+ drainback) <br /> is> 10 '"feet vertical lift from pump to mound taterals, leads to a: <br /> i6) 47 GPM C� 21 feet of head, Pump requirement (note: >SOgpm may require an extra 3-6'of head) <br /> �� 750 gal Dose tank (code minimum) T50 gal Dose tank (design size / LUG req'd) at 26.fl0 ':gpi <br /> leads to a <br /> is> 7.7 inch swing on Demand float, or timed dosing of 4.3 min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow)e9 hrs OFF test and adjust as necessary) <br /> �9� 1?` ` inches from bottom of tank to"Pump OFF'float <br /> 20� 20 inches from bottom of tank to"Pump ON"float, or 12 inches to'Timer ON"float if time dosed <br /> z�) 23 inches from bottom of tank to"Hi Level"float, or 33 inches to"Hi Level"float if time dosed <br /> 22� 152 gallons reserve capacity (after High Level Alarm is activated) <br />