Laserfiche WebLink
�°� <br /> . o 0 <br /> � � ��� � CITY of ORONO <br /> �3 �'�� ' r��� �+ <br /> ��1 ,,� �lCr Municipai Offices <br /> � ���� �'����;�����'°�� _ � Street Address: � � Mailing Addross: � <br /> '�',�;g"g04' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystai Bay; MN 55323•0066 <br /> i <br /> Owner: ��,/��,f� �Y/ (;�,�-�/f Address: 335 Hollander Rd. <br /> Permit #'s: 1404 Dates: li/3/88 Contractors: Perkins Contr. <br /> (This is [}( ] an existing system [ ] new construction) . <br /> /� <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> � Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [�] or is not [ ] identified under this septic system. If the <br /> saturat�d soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out . <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ J or are not [ ] water tight or the condition is [�,] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> INFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 2.2 feet and the system is non-compliant. City Codes do not require repair or <br /> replacement of the septic system at this time. <br /> // a�-9'� <br /> Date of Inspection Se c Syst Insp c or <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />