My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00170 (mechanical)
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2480 Casco Point Road - 20-117-23-21-0037
>
Permits/Inspections
>
2017-00170 (mechanical)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:52:21 PM
Creation date
2/27/2017 9:23:50 AM
Metadata
Fields
Template:
x Address Old
House Number
2480
Street Name
Casco Point
Street Type
Road
Address
2480 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723210037
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect Summa Job: <br />� geothermal � � Date: Feb 08,so�� <br /> rconcepty Entire House By� <br /> Geothermal Concept <br /> P.O.Box444,Ciearwater,MN 55320 Phone:612.481.4020 Email:adam�geotherrnalconcept.com Web:www.geothermalconcept com License: MB652537 <br /> � • • • <br /> For: Rudolph Residence, JN Built <br /> 801 Twelve Oaks Center Drive, Suite 820B, Wayzata, MN 55391 <br /> Phone: 612.321.8350 <br /> Notes: <br /> � - • • • <br /> Weather: Minneapolis/Crystal, MN, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db -16 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 86 °F Design TD 16 °F <br /> Daily range M <br /> Relative humidity 50 % <br /> Moisture difference 37 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 130797 Btuh Structure 53817 Btuh <br /> Ducts 0 Btuh Ducts 0 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 130797 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 0.96 <br /> Infiltration Equipment sensible load 51449 Btuh <br /> nnethod Simp�itied Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 5331 Btuh <br /> Ducts 0 Btuh <br /> Heatin Cooling Central vent (0 cfm) 0 Btuh <br /> Area (ft2 626� 6262 Equipment latent load 5331 Btuh <br /> Volume�ft') 55028 55028 <br /> Air changes/hour 0.28 0.15 Equipment total load 56780 Btuh <br /> Equiv.AVF (cfm) 257 138 Req. total capacity at 0.70 SHR 6.1 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make <br /> Trade Trade <br /> Model Cond <br /> AHRI ref Coil <br /> AHRI ref <br /> Efficiency 80AFUE Efficiency 0 SEER <br /> Heating input 0 Btuh Sensible cooling 0 Btuh <br /> Heating output 0 Btuh Latent cooling 0 Btuh <br /> Temperature rise 0 °F Total cooling 0 Btuh <br /> Actual air flow 2525 cfm Actual air flow 2525 cfm <br /> Air flow factor 0.019 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.91 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 2017-Feb-08 10:18:46 <br /> � WI'Ight50ft` Right-Sufte�Universal 20t7 17.0.04 RSU12703 Page 1 <br /> �� Project2.rup Calc=MJ8 Front Door faces:SE <br />
The URL can be used to link to this page
Your browser does not support the video tag.