Laserfiche WebLink
CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office eox 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWAt;E TREATMENT <br /> � INSPECTION REPORT <br /> � p�� <br /> ��kEsxo�'� <br /> Owner• � / r1��� TT��11(-�� Address• � <br /> Permit #'s: �� Dates: �T Contractors: �� . <br /> City ordinance number 100 requires that each on-site sewage treatment _system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is � an existing system [ ] new construction) <br /> SYSTEM CONFORMITY 1-3 : <br /> 1 ��CODE SYSTEM"-A system �ich meets all the location, design, and construction standards of the current City <br /> Codes, ard which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface uaters. <br /> 2 "CONFORMiNG SYSTEM"-A system which does not meet all the location, design, and construction standards ot the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year tloodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identi ied, this classification may be subject to revision.> <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumutation in tanks indicates they should be a�rnped out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical level. tanks should be punped out as soon as possible. <br /> System is discharging to the surface. Tanks must be p�mped out uithin 48 hours to eliminate surface dischar$e. <br /> Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. i installed �n each <br /> �ank at nexs_�umr�out. If tanks have not been w� ey s ou <br /> out"'T1SiT�'� ' <br /> 10 Inspection pipe is located directly over tank baffle ( o i a u a � a re n of lids accumulation). <br /> If tanks have not been punped out within the last three years, they shoul be pumped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> Dpei�field inspection indicates: <br /> U Y Drainfield is dry, no surfacing evident. <br /> �rz Sane evidence of surfacing, not critical yet. <br /> 73 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> imnediately. Repairs must be campleted within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS Cslope,setbacks,etc.): <br /> POTENTIAI FOR SYSTEM FAILURE (deoends on soils.water table.etc.): /�� <br /> � <br /> COMMENTS: <br /> Date of Inspection Sept System I pector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opim on of the adequacy of the system under current conditions besed on the available <br /> information. <br /> This report must be kept on the premises with the system Locetion and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />