<br /> City Ordinance 199 requires that each existing on-site sewage treatrnent system in Orono be inspected every two years.
<br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
<br /> SYSTEM CONFORMiTY (1-31: �
<br /> - i-- "GODE$YSTEM"An iSTS which meets ail the location,design and construction standards of the current Orono Municipai Code: -
<br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono
<br /> Municipal Code but does meet the three foot separation requirement or two foot requuement for systems iastalled 1996 or earlier,and
<br /> �� which is not failing or an imminent threat W public health or safety.
<br /> ( 3 1 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any IST'S which may
<br /> L� or may not meet all the location,design,or construction stan�ards of the current Orono Municipal Code and wtuch is failing for any
<br /> reason;aad aay ISTS with less Yhan three feet of unsaturated soil or sand between the distribudon device and the limiting soil characteristics.
<br /> TANK CONDI'I'ION(5-71:
<br /> Tank inspection indicates:
<br /> 5 Pumpout not needed atthis time. '-
<br /> �Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
<br /> Tank was last pumped "L—\�-Q°\ ).
<br /> Make sure seatic tanks are aumaed through manhole and not throug6 white insuection aiaes. T6is allows for the proaer
<br /> cleanine. Keea water softner and iron filter discharee out of septic svstem to urolon¢life of drainfield. Ask uumaer to test
<br /> alarm float to verifv alarm is stilt working in vour house. The alarm warns owner that septage is about to backua into basemen�
<br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
<br /> tanks have not been pumped out within the last three years,they should be pumped out now.
<br /> �D INFIELD CONDITION(8-101: �
<br /> Drainfield is dty,no surfacing evident.
<br /> 9 Some evidence of surfacing,not critical yet.
<br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
<br /> immediately.Repairs must be completed within 90 days.
<br /> . �c.��;,C,�,� ... -,- 1S _ :. r�d�.- C�... .���n,-�_., :.-.,..� ,,`v ,�j� .:
<br /> ' ;
<br /> COMIvIEN�S: ,`
<br /> �c. \�+C c \'Zr �- Z010 � U �( -j'��- .k5 L^�nc� Z,odS.
<br /> k��z-vu �1��
<br /> Date of Inspection Matt Bolterman - Septic System Inspector