Laserfiche WebLink
�°� <br /> 0 0 <br /> � �� T� CITY of ORONO <br /> \� ix <br /> �i, r���;� '�+ <br /> � 4' e�' . '',� -� � MIlIl1C1� D�CeS <br /> � ` �� i ~ <br /> � ��� � f;;� `e��'�G Street Addressa Mailing Address: <br /> '�fEgg04' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> Owner: �� � Address: 280 Hollander Rd. <br /> Permit #'s: 5874 Dates: 12/20/79 Contractors: Sullivan <br /> (This is (l�C] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> O Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is �.] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.). <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been um ed out within three ears the should be pum ed out now. � <br /> 10 ne or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ ] water tight or the condition is [�] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to reviss.on.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 0 feet and the system .is non-compliant. Repair or replacement of the septic <br /> system is required by 12/31/2005. <br /> /i- av - � � <br /> Date of Inspection e System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />