My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
H
>
Hollander Road
>
260 Hollander Road - 25-118-23-43-0013
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:49 PM
Creation date
2/22/2017 12:40:32 PM
Metadata
Fields
Template:
x Address Old
House Number
260
Street Name
Hollander
Street Type
Road
Address
260 Hollander Road
Document Type
Septic
PIN
2511823430013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Office eox 66 <br /> Crystal eay, MN 55323-0066 � � ON—SITE SEWA(�E TREATbISNT <br /> IN3PECT�ON REPORT <br /> ti <br /> ��� �G <br /> 9kEsHo�' <br /> ' �� �ll r,�! I� <br /> Owner: Address: /� �V i <br /> .� <br /> Permit #�'s: Datea: D�(�—Q \ Contractors: �C� ��G r <br /> City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is �an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (t-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface uaters. <br /> 3 "NON-C�IFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which mey or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting so�l characteristics. <br /> (The limitin� soil characteristic � has or [ ] has not been identified at this time. if the limiting soil <br /> characteristic has not been identi ied, this classification may be subject to revision.) <br /> TANK CONDITION CS-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accunulation in tanks indicates they should be aunaed out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each <br /> tank at next punpout. lf tanks have not been punped out within the last three years, they should be p�mped <br /> out now. <br /> Inspection pipe is located directly over tank baffle ' e measurement of solids accumulation). <br /> If tanks have not been ptmped out within the last three years, they s ou <br /> DRAINFIELD CONDITION (11-14): <br /> Dr,djnfietd inspection indicates: <br /> q,y Drainfie[d is dry, no surfacing evident. <br /> 7z Same evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repeirs must be canpleted within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING S1TE fACTORS Csloce.setbacks,etc.): <br /> POTENTIAL POR SYSTEM fAILURE Cdeaends on soils,water table.etc.): /)')P/ ���,� <br /> y�tr <br /> COMMENTS: <br /> Date of Inspection Septi Syste nspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system w�ll continue to function <br /> properly� but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the pre�nises with the system location and punping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner • <br />
The URL can be used to link to this page