Laserfiche WebLink
CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITS SEWAf3E TREA'1'l�NT <br /> INSPECTION REPORT <br /> ti <br /> ��9k o4�G <br /> ESH <br /> Owner• ���Address• <br /> Permit #'s: Dates: /��'� Contractors: . <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is �, an existing system [ ] new construction) <br /> S1'STEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any potlutants into ground or surtace waters. <br /> 3 "NON-CONFORMING SYSTEM°-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and eny.system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting so�l characteristics. <br /> (The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identi ied, this classification may be subject to revision.> <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> ,S� Punpout not needed at this time. <br /> �y Solids accunulation in tanks indicates they should be out this ear to hel revent future roblems. <br /> 7 o i s accumu a ion in a <br /> 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface�dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe> must be instatled in each <br /> tank at next punpout. lf tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 lnspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> !f tanks have not been punped out within the last three years, they should be punped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> Dr field inspection indicates: <br /> 11 Drainfield is dry, no surfacing evident. <br /> `4'L Sane evidence of surtacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING S1TE FACTORS Csloae.setbecks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (deoends on soits.water table.etc.): ���yr�.� <br /> COMMENTS: <br /> Da e of Inspection p ic Sys em nspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> property� but is merely an opim on of the adequacy of the system under current conditions based on the avaitable <br /> informet�on. <br /> This report must be kept on the premises with the system locetion and Fxmping records. <br /> WHITE COPY/Inspectors F(le YELLOW COPY/Homeowner <br />