My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
H
>
Hollander Road
>
250 Hollander Road - 25-118-23-43-0027
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:16:06 PM
Creation date
2/22/2017 11:54:24 AM
Metadata
Fields
Template:
x Address Old
House Number
250
Street Name
Hollander
Street Type
Road
Address
250 Hollander Road
Document Type
Septic
PIN
2511823430027
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i ~O�\ <br /> � � � . � . .._ . � . <br /> ,� ,. <br /> .:.� . � _. .."�.�-� . �".: ,�,.-.. . ,.`._. , _.. ...._. . .. . - � <br /> � <br /> �'� � <br /> ;' ,� L . �.�'' . . <br /> �� ���= CITY of ORONO <br /> ,,,.;n�:r� <br /> . ,� ,a, . ���� � <br /> ,,�, �f� ,�. ��� �.�' �l�r Municipal Offices <br /> ��;�?,ti;,.. . ;��.. �:v <br /> � t�� :�.'r��� �,,t�.�G Street Address: °I Sa-a4 9-�6o O �Iailing Address• <br /> `'$�Hp�' 2750 Kelley Parkway � P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ��� Ho1 I a�a et' �� � = . <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. �. <br /> SYSTEM CONFORMITY (1-3): � <br /> --- ---- ---1- "COD$SYSTEiV1"An ISTS which meets all the locafion,design and construction standards of the current Orono Municipai Cozie. - - - - -�-�— <br /> 2 "COMPLIANT SYSTEM" An LSTS wluch does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requ'uement for systems iastalled 1996 or earlier,and <br /> which is not failing or an i�inent threat to public heatth or safety. <br /> ( 3 )"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> `�or may not meet all the locarion,design,or construction stanc�rds of the current Orono Municipal Code and which is failing for�ny <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the dishibution device and the limiting soil characteristics. <br /> TANK CONDITTON(5-7): � <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. � <br /> 6 Septic tanks must be pum ed out this year (city code recommends tanks to be pumped out once every 3 yeazs, . <br /> Tank was last pumped ��\-03 ). . <br /> Make sure seatic tanks are Qumaed throush manhole and not throu¢h white insaection aipes. This ailows for the proaer . <br /> cleanin¢ Keea water softner and iron filter discharae out of seatic svstem to arolon¢life of drainfield. Ask oumaer to test , ' <br /> alarm float to verifv alarm is stiil workin¢in vour house. T6e alarm w�rns owner that seata¢e is about to backuu into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be instailed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDTTION f8-10): � <br /> �Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. � <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector. <br /> immediately.Repairs must be completed within 90 days. <br /> [�.�;-e��, �S r0 c•�- (d h�`*G�'�r`.- :r�..�.. . _,��_5,�. .. . ,.;�� r.. . .; <br /> COMMEN S: . Q � ., . <br /> {�Q\o�c c �-y 1L� 1 -ZO \0 . <br /> � -���o� �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this repori dozs <br /> nut guarantee or certify that an e�isting system �vill continue to functioit properly. but is merely an opinion of the adequacy of the spstem under current <br /> cunditions based on the availablc information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.