2000-P02995 - mechanical
Orono
>
Property Files
>
Street Address
>
H
>
Hollander Road
>
225 Hollander Road - 25-118-23-44-0007
>
Permits/Inspections
>
2000-P02995 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:16:11 PM
Creation date
2/22/2017 11:23:29 AM
Metadata
Fields
Template:
x Address Old
House Number
225
Street Name
Hollander
Street Type
Road
Address
225 Hollander Road
Document Type
Permits/Inspections
PIN
2511823440007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� . <br /> ��tHVAC-Re$idential8 Light Commerciai HVAC Loads Program Elite Software Development,lnc. <br />� Ditter,Inc. � ' NeumannlMcMtltan <br /> Hamel,MN 55340-9691 09-16-2000 ' Page 2 <br /> Project Summary <br /> Project: Neumann/McMillan Company: Ditter Inc., Cooling and Heating <br /> Client: Neumann/McMillan Representative: Doug Bjork <br /> Address: 225 Hollander Rd Address: 820 Tower Drive <br /> City: Orono, MN City: Medina, MN. 55340 <br /> Phone: Phone: (612)478-9558 <br /> Fax: Fax: (612)478-9524 <br /> Comment: <br /> Design Da#a <br /> Project Name: Neumann/McMillan <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum. Drv Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 <br /> Check Figures <br /> Total Building Supply CFM: 1828 CFM per square foot: 0.716 <br /> Square feet of room area: 2,554 Square feet per ton: 604.807 <br /> Building:Loads <br /> Total heating required with outside air: 92,427 Btuh 92.427 MBH <br /> Total sensible gain: 39,019 Btuh 85 % <br /> Total latent gain: 7,091 Btuh 15 % <br /> Total cooling required with outside air: 46,110 Btuh 3.842 Tons(based on sensible+latent) <br /> 4.223 Tons(based on 77% sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Saturday,September 16,2000 <br />