Laserfiche WebLink
< < <br />� DRAWING SCOPE 8 USE (CUIDELINES <br /> SCOPE OF WORK <br /> THESE YEAR 2007 CAST-IN-PLACE (C.I.P.) CONCRETE FOUNDATION DRAWINGS, CONSISTING <br /> OF S-1 THROUGH S-8 AND DATED 1-1-07, ARE PREPARED BY ULTEIG ENGINEERS, INC. <br /> THESE DRAWINGS CONTAIN STRUCTURAL DESIGN INFORMATION AND DETAILS TO BE USED <br /> IN THE CONSTRUCTION OF CAST-IN-PLACE CONCRETE FOUNDATIONS FOR VARIOUS <br /> CONDITIONS COMMON WITHIN THE RESIDENTIAL MARKET ONLY. THE INFORMATION IS <br /> INTENDED FOR THE CONCRETE CONTRACTOR, AS WELL AS THE GENERAL CONTRACTOR <br /> AND THE FRAMING CONTRACTOR. <br /> THESE DRAWINGS ARE CERTIFIED AND PREPARED TO THE REQUIREMENTS OF THE <br /> INTERNATIONAL RESIDENTIAL CODE (IRC), AS WELL AS THOSE OF THE MINNESOTA AND <br /> WISCONSIN STATE BUILDING CODES. THESE DRAWINGS ARE VALID THROUGH DECEMBER <br /> 31, 2007. <br /> THESE DRAWINGS ARE LICENSED THROUGH AN AGREEMENT BETWEEN ULTEIG AND THE <br /> LICENSEE NOTED IN THE TITLE BLOCK BELOW. THESE DRAWINGS ARE TO BE USED <br /> SOLELY FOR PROJECTS IN WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THESE <br /> DRAWINGS MAY BE RELEASED BY THE LICENSEE TO ITS AGENTS, SUB-CONTRACTORS, <br /> AND CLIENTS FOR THE USE IN PROCUREMENT OF BUILDING PERMITS ONLY. ALL OTHER <br /> USES ARE PROHIBITED. <br /> USE GUIDELINES � <br /> FOR EACH PROJECT, THE LICENSEE IS TO INDICATE THE APPLICABLE SHEETS OF THE <br /> DRAWINGS ON THE INDEX SHEET AND THEN SUBMIT THEM WITH THE FULL CONSTRUCTION <br /> DOCUMENT PACKAGE TO THE APPROPRIATE CITY BUILDING DEPARTMENT AT THE TIME OF <br /> PERMIT APPLICATION OR IN ACCORDANCE WITH AN ALTERNATIVE METHOD APPROVED BY <br /> THE CITY. THE CITY BUILDING INSPECTIONS DEPARTMENT WILL REVIEW THE DRAWINGS <br /> AND USE THEM DURING FOUNDATION INSPECTIONS TO ENSURE COMPLIANCE. <br /> THESE DRAWINGS ARE PRIMARILY APPLICABLE TO THE FOLLOWING CONDITIONS: <br /> 1. BASEMENT WALLS TEN FEET OR LESS IN CLEAR HEIGHT <br /> 2. OVERALL BUILDING HEIGHT NOT EXCEEDING TWO STORIES PLUS A BASEMENT <br /> 3. ROOF SPANS NOT EXCEEDING FORTY FEET CLEAR <br /> 4. FLOOR SPANS NOT EXCEEDING TWENTY FEET CLEAR <br /> 5. WOOD JOIST, LUMBER, OR TRUSS FLOOR AND ROOF SYSTEMS <br /> 6. CANTILEVERED CONCRETE WALLS NOT EXCEEDING FOUR FEET IN HEIGHT <br /> SPECIAL CONSIDERATION AND DESIGN MAY BE REQUIRED FOR CONDITIONS BEYOND <br /> THESE LIMITS. <br /> MATERIALS <br /> CONCRETE: MIX IS TO BE DESIGNED BY THE CONCRETE SUPPLIER <br /> F'C = 3,000 PSI (MINIMUM STRENGTH @ 28 DAYS) <br /> STEEL: #5 BARS 8 GREATER — FY = 60 KSI (ASTM A615) <br /> #4 BARS — FY = 40 KSI (ASTM A615) <br /> 2007 MASTER CAST-IN-PLACE CONCRETE ADVANCED CONCRETE CONSTRUCTION, INC. <br /> FOUNDATION DRAWINGS 432 LILAC ST.LINO LAKES,MN 55014 <br /> SCOPE, USE GUIDELINES,8 MATERIALS Phone:(651)784-2450 Fax:(651)784-2523 <br /> 5201 East River Roatl Suite 308 JOB SITE INFORMATION Revision Dale Destription <br /> Minneapolis,Minnesola 55421 � (to be IiNeA out Dy the crontractw) <br /> Pho�e:�63.57t.2500 Fax: 763.571J168 p�y�r: <br /> Bismard-Deddl Lakes-Fargo�MinneapoFs�Siouz Falls <br /> Web:www.ultei9.com Street Address: <br /> � •' <br /> -�engineers DrawnBy:TroyDeGroot ProjectNumber. 206.7200 ^`' D <br /> ChedcedBy:TrevorAxner Date: Januarvt.2007 J�� D <br /> Approvetl By:Craig Oswell Ciry: State'_Zip Cotle:_ Shee�s . 2 of 26 <br /> QC COPYRIGHT ULTEIG ENGINEERS INC.2007 <br />