Laserfiche WebLink
Heatin <br /> 1. Furnace is missing doors and appeazs to be non-functional. Furnace hazazdous <br /> within the definition of Minnesota Statute Section 463.15, Subd. 3. <br /> Electrical S, s�� <br /> 1. Electrical system has open, deteriorated wiring - entire system needs upgrading. <br /> Electrical system is hazardous within the definition of Minnesota Statute Section <br /> 463.15. <br /> NOW,THEREFORE,BE IT RESOLVED as follows: <br /> 1. The City Council of the City of Orono,Minnesota,pursuant to the foregoing findings <br /> and in accordance with Minnesota Statutes Section 463.15 to 463.261,hereby orders <br /> the owner of the property to remove the structure or to make the following repairs in <br /> order to correct the hazardous conditions: <br /> Foundation <br /> — Footing and foundation-replace with code compliant materials. <br /> — Backfill with earth sloped away from building with positive drainage. <br /> — Provide code compliant egress window. <br /> Floar S, s� <br /> — Replace floor system with code compliant materials a minimum of 18 inches <br /> from earth. <br /> Stairwavs <br /> — Reconstruct stairways with code compliant materials including proper rise <br /> and run, headroom, and handrails and guardrails. <br /> Exterior <br /> — Support fuel tank on proper base. <br /> — Raise building or lower grade to provide 6 inch clearance from earth to <br /> framing. <br /> — Replace porch wall with code compliant material. <br /> — Replace siding, so�t, and facia where needed. <br /> Page 3 of 5 <br />