My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-00005 - new structure
Orono
>
Property Files
>
Street Address
>
H
>
Highwood Road
>
4156 Highwood Road - 07-117-23-44-0019
>
Permits/Inspections
>
2013-00005 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:40:14 PM
Creation date
2/15/2017 3:10:06 PM
Metadata
Fields
Template:
x Address Old
House Number
4156
Street Name
Highwood
Street Type
Road
Address
4156 Highwood Rd
Document Type
Permits/Inspections
PIN
0711723440019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL NOTES <br /> Unless noted otherwise on the plans and/or 1n the detalls,these notes shall apply. If there are <br /> discrepancies between the plans/details and these notes,the contractor shall conform to the more <br /> stringent requirements, unless clarified with the Structural Engineer of Record (SER)prior to <br /> work. <br /> MATERIAL STRENGTHS <br /> Structural Steel <br /> HSS Rectangular—ASTM A500 Gr. B, Fy=46 ksi <br /> Misc. structural steel—ASTM A36, Fy=36 ksi <br /> Electrodes E70xx or equivalent wire <br /> Structural Steel Fasteners <br /> Anchor rods—ASTM F1554, Gr.36, Fy=36 ksi <br /> Threaded rods—ASTM A36, Fy=36 ksi <br /> Reinforcing Steel <br /> Deformed Bars—ASTM A615, Gr. 60, Fy= 60 ksi <br /> Masonry Joint Reinforcing—ASTM A951, Fy=70 ksi <br /> Epoxy Coating for Reinforcing Steel—ASTM A775 <br /> Concrete <br /> f'c=compressive strength in 28 days <br /> 4,000 psi unless noted otherwise <br /> 3,000 psi for footings <br /> 3,000 psi for masonry corefill &concrete topping on precast <br /> Structural Lumber <br /> All dimensional lumber-#2 Spruce Pine Fir(SPF) or equal <br /> Laminated Veneer Lumber(LVL) <br /> E= 1,900,000 psi <br /> Fb=2600 psi <br /> Parallel Strand Lumber(PSL) <br /> E=2,000,000 psi <br /> Fb-2900 psi <br /> Treated lumber-#2 Southern Pine or equal <br /> DESIGN LOADS <br /> Roof <br /> Dead load <br /> 17 psf(7 psf top chord+ 10 psf bottom chord) <br /> Snow load <br /> Roof snow load =35 psf <br /> Floors <br /> Dead load <br /> 15 psf(5 psf top chord+ 10 psf bottom chord) <br /> Live loads <br /> Typical 40 psf <br /> Habitable attics and sleeping areas 30 psf <br /> Garage Parking <br /> 50 psf or 2000 pound point load plus topping weight <br /> Wind <br /> 90 mph (3 second gust) <br /> Exposure B, I = 1.0 <br /> EXISTING CONDITIONS <br /> Contractor shall verify all dimensions, elevations, and details of existing structure where they affect this <br /> construction prior to fabrication. <br /> Remove and replace existing architectural, electrical, mechanical, structural, civil, and miscellaneous as <br /> necessary. <br /> Appendix A,Highwood Road Residence,23Jan2013,MMY#: 13042.00,APG <br /> Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.