<br /> � CLAD ULTIMATE DOUBLE HllNG Builtaroundyou:
<br /> NFRC VALUES
<br /> NFRC Unit Values
<br /> Solar Heat
<br /> Glazing Type U-Factor Gain Visible Light Condensation
<br /> Coefficient Transmittance Resistance Energy Star
<br /> Double Hung/Single Hung
<br /> Size Tested 47 x 59 47 x 59 47 x 59 47 x 59
<br /> Insulating Low E II glass-Argon,SDL with spacer bars 0.33 0.27 0.45 - N,NC,SC,S
<br /> Insulating LoE3-366"" Glass 0.34 020 0.46 51 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon 0.31 020 0.46 54 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/Spacer Bar<1" 0.35 0.18 0.41 51 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/Spacer Bar>1" 0.35 0.16 0.36 51 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/o Spacer Bar<1" 0.34 0.18 0.41 51 N, NC,SC,S
<br /> Insulating LoE3-366 Glass- SDL w/o Spacer Bar>1° 0.34 0.16 0.36 51 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/Spacer Bar<1" 0.31 0.18 0.41 54 N,NC,SC,S
<br /> Transom 3/4"IG
<br /> Size Tested 47 x 59 47 x 59 47 x 59 47 x 59
<br /> Insulating LoE3-366"" Glass 0.32 0.22 0.50 54 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon 0.29 0.21 0.50 58 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/Spacer Bar<1" 0.33 0.20 0.44 54 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/Spacer Bar>1" 0.33 0.18 0.39 54 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/o Spacer Bar<1" 0.32 0.20 0.44 54 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/o Spacer Bar>1" 0.320 .018 0.39 54 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/Spacer Bar<1" .029 0.19 0.44 58 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/Spacer Bar>1" 0.29 0.18 0.9 58 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/o Spacer Bar<1" 0.29 0.19 0.44 58 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/o Spacer Bar>1" 0.29 0.18 0.39 58 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-GBG 0.33 0.20 0.44 54 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,GBG 0.29 0.19 0.44 58 N,NC,SC,S
<br /> Picture 1"IG
<br /> Size Tested 48 x 48 48 x 48 48 x 48 48 x 48
<br /> Insulating LoE3-366'" Glass 0.32 021 0.47 56 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon 0.28 0.20 0.47 59 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/Spacer Bar<1" 0.33 0.19 0.42 56 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/Spacer Bar>1" 0.33 0.17 0.37 56 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/o Spacer Bar<1° 0.32 0.19 0.42 56 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-SDL w/o Spacer Bar>1" 0.32 0.17 0.37 56 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/Spacer Bar<1" 0.29 0.18 0.42 59 N,NC,SC,S
<br /> Insulating Lo�3-366 Glass-Argon,SDL w/Spacer Bar>1" 0.29 0.17 0.37 59 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/o Spacer Bar<1" 0.28 0.18 0.42 59 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,SDL w/o Spacer Bar>1" 0.28 0.17 0.37 59 N,NC,SC,S
<br /> Insulating LoE3-366 Glass-GBG 0.32 0.19 0.42 56 N, NC,SC,S
<br /> Insulating LoE3-366 Glass-Argon,GBG 0.28 0.18 0.42 59 N, NC,SC,S
<br /> NOTE:
<br /> Product Values are determined using the National Fenestration Rating Council(NFRC)Procedures for determining fenestration product values.
<br /> U-Value:(Btu/hr-sq ft-'�Lower the U-Value,Ihe greater the resistance to heat flow and better its insulating value.
<br /> R-Value: (1/U-Value)Higher the R-Value,the greater the resistance to heat flow and better its insulating value.
<br /> Visible Light Trensmittance(VL�: Percentage of visible light transmitted through the unit.
<br /> Solar Heat Gain Coefficient(SHGC): The lower a window's SHGC,the less solar heat it transmits,and the greater its shading ability.
<br /> Condensation Resistance(CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interior
<br /> surface of a producLThe higher the CR rating,the better that product is at resisting condensation formation.
<br /> Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.
<br /> Contact the Architectural Department Hotline at(800-346-3363)for additional NFRC Unit Values.