My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00589 - new septic
Orono
>
Property Files
>
Street Address
>
H
>
High Lane
>
3445 High Lane - 05-117-23-12-0025
>
Septic
>
2009-00589 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:16:18 PM
Creation date
1/26/2017 2:46:52 PM
Metadata
Fields
Template:
x Address Old
House Number
3445
Street Name
High
Street Type
Lane
Address
3445 High La
Document Type
Septic
PIN
0511723120025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�,�m�.,��..�. <br /> � Design Ftow and Soit Worksheet � � :_ �x�� . �� <br /> Minnesota Pollution " �' <br /> � a.�, <br /> Control Agency ��' �"*. . <br /> 1. AVERAGE DESIGN FLOW: <br /> Note: The estimated design flow is considered a peak <br /> A. Estimated Design Flow(GPD): 450 �� f(ow rate including a safety factor. For long term <br /> performance,the average daily flow is recommended <br /> or Meosured Flow(GPD):flow times safety factor to be<60%of this value. <br /> � �� X � ��Pd <br /> Design Flow: 450 Gallons Per Day(GPD) System Type <br /> B. Septic Tnnk capacity: 2000 Gallons �Type I ❑ryPe tt ❑rype ut ❑ryPe rv ❑rype v <br /> Number of Septic Tanks or Compartments: � Efftuent Screen&Alnrm? Yes <br /> Table 1- Design Flow(Gallons Per Day) Table il-Septit Tank Capacity <br /> Number of Classification of Dw�elling Number of $�tic Tank Liquid lVYrlimum Capatity with Garbage Disposal and/or <br /> Bedrooms I II lu �� g�rooms Capacities(Galbns) Sewage Pumped to Tank` <br /> 2 or less 300 225 180 ' 3 or less 1,000 1,500 <br /> 3 450 300 218 ' <br /> 4 b00 375 256 ' 4 or 5 1,500 2,250 <br /> 5 750 450 2g4 ` 6 Or 7 2,000 3,000 <br /> 6 900 525 332 " 8 Or 9 2,500 3,750 <br /> 'Flows for Ctassification IV dwellings are 60 percent of the values as determined for Classification I, II or III systems. <br /> 2. SITE EVAIUATION: <br /> Texture Gro� <br /> A. Depth to Limiting Layer: 24 inches 2.0 ft <br /> Soil Texture Group a <br /> Type of Soil Treatrnent and Dispersal Area Coarse Sand 1 <br /> B. Nledium Sand 2 <br /> �Trenches �Bed �At-Grade �Mound Fine Sand 3 <br /> Coarse Loamy Sand 4 <br /> Medium Loamy Sand 4 <br /> Type of Distributlon Fine Loamy Sarxf 5 <br /> �. Very Fine Loamy Sand 5 <br /> �Gravity Distribution 0 Pressure Dis�ibudon-Level 0 Pressure Distribution-Unlevel Coarse Sandy Loam 6 <br /> Medium Sandy Loam 6 <br /> Fine Sandy Loam 7 <br /> Very Fine Sandy Loam 7 <br /> D. Landscape Position: Back/ Side Slope ��m s <br /> Silt Loam 9 <br /> Clay Loam 10 <br /> E. Estimated Percent Land 5(ope: 12•0 90 Silty Clay Loam io <br /> Sandy Clay Loam 10 <br /> Of Silty Clay 11 <br /> Rise Run sandy Ctay 11 <br /> F. Catculated Slope = � : � x 100= � Clay �i <br /> L�J <br />
The URL can be used to link to this page
Your browser does not support the video tag.