My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00577 - new septic
Orono
>
Property Files
>
Street Address
>
H
>
High Lane
>
3415 High Lane - 05-117-23-12-0017
>
Septic
>
2009-00577 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:16:10 PM
Creation date
1/26/2017 2:03:49 PM
Metadata
Fields
Template:
x Address Old
House Number
3415
Street Name
High
Street Type
Lane
Address
3415 High La
Document Type
Septic
PIN
0511723120017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
���i..us�.,������.�.�s�n., <br /> ' MinnesotaPoliution Design Flow and Soil Worksheet <br /> Controi Agency <br /> 1. AVERAGE DESIGN FLOW: <br /> Note: The estimated design flow is considered a peak <br /> A. EStimated Design Flow(GPD): 450 �Pd itow rate inctuding a safety factor. For long term <br /> performance, the average daily flow is recommended <br /> or Mensured Flow(GPD):flow times safety factor to be<60%of this value. <br /> � �pd X � ��Pd <br /> Design F(ow: 450 Gallons Per Day(GPD) System Type <br /> B. Septic Tank capacity: 2000 Gd��p�5 �TNP�I ❑Type II ❑Type III ❑Type N ❑Type V <br /> Number of Septic Tanks or Compartments: � Effluent Screen 8 Alarm? Yes <br /> Table I-Design Flow(Gaibns Per Day) Table II-Septic Tdnk CapaCity <br /> Number of Classification of Dwelling Number of Septic Tank Liquid Atirrimum Capacity with Garbage Disposal and/or <br /> Bedrooms 1 II ��� � g�rooms Capacities(Galbnsj Sewage Pumped to Tank* <br /> 2 or tess 300 225 180 ` <br /> 3 450 300 21 g • 3 or tess 1,0(l0 1,500 <br /> 4 600 375 256 • 4 or 5 1,500 2,250 <br /> 5 750 450 294 ` 6 01"7 2,000 3,000 <br /> 6 900 525 332 ' 8 Or 4 2,500 3,750 <br /> •Flows for Ctassification IV dwetlin�s are 60 percent of the values as determined for Classification I, II or III systems. <br /> 2. SITE EVALUATION: <br /> Texture Group <br /> A. Depth to Limiting Layer: 3$ inches 3•2 ft <br /> Soil Tenture Group M <br /> Type of Soil Treatrnent and Dispersal Area Coarse Sand 1 <br /> B. Medium Sand 2 <br /> �Trenches �Bed �At-Grade �Mound Fi��� 3 <br /> Coarse Loamy Sand 4 <br /> Medium Loamy Sand 4 <br /> Type of DistribuGon Fine Loamy Sa�d 5 <br /> C, Very Fine Loamy Sand 5 <br /> �Gravity Distribution �Pressure Distribution-Level �Pressure Distribution-Unlevel Coarse Sandy Loam 6 <br /> Medium Sandy Loam 6 <br /> Fine Sa�y Loam 7 <br /> Very Fine Sandy Loam 7 <br /> D. Landscope Positron: Foot Slope ��m 8 <br /> Silt Loam 9 <br /> Clay Loam 10 <br /> E. Estimated Percent Land 5lope: 15-� % Silty Clay Loam io <br /> Sandy Clay loam 10 <br /> °f Rise Run Silry Clay �i <br /> Sandy Ctay 11 <br /> F. Ca(culated S(ope = � � x 100= � ctay i i <br />
The URL can be used to link to this page
Your browser does not support the video tag.