Laserfiche WebLink
� O� <br /> O O <br /> ,, r�♦, � C ITY of ORONO <br /> ,� ,� <br /> ��;' � �, Municipal Offices <br /> ` � ti <br /> � �'\" G Street Address: Mailing Address: <br /> �`9$ESKQg'� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> � <br /> Owner: �1S}�_���, �P���0 Address: 1190 Haritage Ln. <br /> Permit #'s: none Dates: Contractors: unknown <br /> (This is �] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> � codes and is functioning properly. <br /> � 3) Non-Compliant System: System may or may not meet current City standards for design, <br /> � construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil lavel is [�] or is not [ ] identified under this septic system. If the <br /> saturatad soil leval is not identifiad, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 10 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not ['�] water tight or the condition is [ ] unknown. If the tanks <br /> are not confirmed to ba waterti�ht, this classification is subjact to revision.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 5ome evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMMENTS: The septic system is classified as a failing system since the tanks have no bottoms. <br /> The system must be repaired, replaced or connected to municipal sewer by 12/31/2005. <br /> (Municipal sewer may or may not be available to you. ) <br /> < < — <br /> Date of nspection S tic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />