Laserfiche WebLink
�p Bunkers & Associates LLC <br /> a structura engineers <br /> 6687 Forest Street <br /> Farmington, MN 55024 <br /> 651.366.2853 <br /> Date: May 12, 2016 <br /> To: Rehkamp Larson Architects, Inc. <br /> 2732 West 43�d St. <br /> Minneapolis, MN 55410 <br /> Attn: Amanda Kay <br /> From: Eric Bunkers <br /> Project: Markusen Residence <br /> 1135 Heritage Ln. <br /> Orono, MN 55391 <br /> Proj. No: 16134 <br /> Subject: Proposed Remodeling <br /> Dear Amanda: <br /> As requested, we designed new structural members for the above referenced project. We have designed the <br /> new members using a roof and floor dead load of 15 psf, a roof snow load of 35 psf, and a floor live load of <br /> 40 psf in accordance with the Minnesota State Building Code. Our work only includes designing the new <br /> members as shown at the above reference project and is based on drawings provided by you and from our <br /> conversations. <br /> Attached are S10—S12 structural sheets with annotated framing and foundation notes and details showing <br /> the new members and connections. All framing and foundations shall be shored and temporarily braced as <br /> required by the contractor and all minimum nailing shall be in accordance with IRC Table R602.3(1). Lumber <br /> shall be minimum #2 SPF with treated lumber to be#2 S. Pine and engineered lumber to have Fb =2600 psi <br /> with E =2.0. Our calculations assume all lumber is of good quality and does not have large splits and <br /> checks and shall be visually inspected by the contractor at the time of construction. All fasteners in contact <br /> with treated lumber shall be G185 hot dipped galvanized or equal. Rebar shall be grade 60. Steel plate shall <br /> meet ASTM A36 and steel tube shall meet ASTM A992. <br /> Concrete used for footings shall have a 28 day compressive strength of 5000 psi and masonry core grout <br /> shall have a 28 day compressive strength of 3000 psi. The new footings have been designed as a typical <br /> spread footing based on a presumptive load-bearing value of 2000 psf in accordance with Table R401.4.1 of <br /> the IRC. The existing footings have been assumed to be typical spread footings on good soils that are <br /> assumed to be pertorming adequately. The contractor shall also verify the condition of structural members <br /> and foundations affected by the remodeling. Exterior grade shall slope away from the building and gutters <br /> with long downspouts should be used whenever possible. Foundation backfill shall be granular and the <br /> foundation system is assumed to have drain tile. Our intention is to visit the project once framing is complete <br /> to get on overview of the framing and become generally familiar with the work. <br /> REC�I�/ED <br /> M��`f 2 3 2016 <br /> CITY OF ORONO <br />