Laserfiche WebLink
�1 � \ <br /> 7 • � , <br /> � o \�',,. : . . _ . <br /> �� _ '' �i���O� ����� <br /> ,; <br /> r .� <br /> ,�';:}, ;�*'+ �►r <br /> �',, ��! ,,. ���:` � �l� Municipal Offices <br /> � ;:�;,t,�; <br /> .l " " �t�.�`r� ``�`�,G Street Address: q5a-a�{q—�6o � Mailing Address: <br /> `9�t'Eg'g0�' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �(3� �«� �c�e-- l ��� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-3): � <br /> "CODE SYS1'EjV1" An ISTS which meets all the location,design and construction standards of the cutrent Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement ot two foot requuement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may noi meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7}: 3 <br /> Tank inspection indicates: <br /> � Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �1'�-�1'0� ). <br /> Make sure septic tanks are pumRed throuQh manhole a�d not thi•ouQh white inspection pipes. This allows for the proper <br /> cleaninQ. Keep water softner and iron filter discharee out of septic svstem to prolon�life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workinE in vour house. ThE atarm warns owner that septage is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. , <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> _ COMMENTS: Qc�-��.-c1� .._. �— S<p }-.Z '�'F�lf 5- .. '�pl� (� <br /> �s-�-o� �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: ln the event that this inspection report is used to satisf'y the requirements for a mortgage or other transfer of property, be advised that this report does <br /> nut �uarantee or certif)� diat an existing system will continue to function properl}�, birt is merely an opinion of the adequac�• of the s�srem undcr cwreni <br /> �unditions bascd on[he availablc inlorniation. <br />