Laserfiche WebLink
� -o� <br /> : �. � _ ...: _�:. <br /> ,o o���,�� . <br /> '� - _ ��TY of ORO1�T� <br /> �; <br /> � r:;r.�. ,� <br /> � ''4`�; ;�. ,,�'�.` � Municipal Offices <br /> '� ,:,,�,. ,.. �� <br /> ,t ' � ��;;`� '•`�'��' Street Address: �15a-a�-f q-y 6o O Mailing Address: <br /> '9kESKp� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ���� �c� ���'J� `"�1��- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code� <br /> 2 "COMPLIANT SYST'EM" An LSTS which does not meet all the location,design and construction standazds of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or trvo foot requirement for systems instafled 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIAN'T SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may oot meet all the location,design,or construction stan�ards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand beriveen the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): �� <br /> T k inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �"Z-S'Gy ). <br /> Make sure septic tanks are pumped throu�h manhole and not throu�h white inspection pipes. This allows for the proper <br /> cleanin� Keep water softner and iron filter discharQe out of septic svstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is stitt working in vour house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> INFIELD CONDITION 8-10 : 2l <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: 1�f q,��:c,\U _ �— St��,� �ItS . ��°� ��- <br /> c",�JO� � � <br /> Z5 <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: fn the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not suarantee or certif} that an existing sysrem wi(I continue to ftuiction proper(��, but is merely an opinion of the adequacy of the s�stem und�r current <br /> cunditions based on d�e available inlonnation. <br />