My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
H
>
Heritage Lane
>
1005 Heritage Lane - 10-117-23-12-0005
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:18:39 PM
Creation date
1/24/2017 10:49:23 AM
Metadata
Fields
Template:
x Address Old
House Number
1005
Street Name
Heritage
Street Type
Lane
Address
1005 Heritage Lane
Document Type
Septic
PIN
1011723120005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� °� <br /> 0 0 <br /> , ;�,� � C ITY of ORONO <br /> � r�w. � <br /> y , ti MunicipalOffices <br /> ti <br /> �,�9 g.�G Street Address: Mailing Address: <br /> $ESHp 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: ��7��� ���C.�� Address: 1005 Haritage Ln. <br /> Permit #'s: 3772, 7499 Dates: 8/28/73, 7/il/84 Contractors: Widmer Bros., E. J. Peterson <br /> Co. <br /> (This is [x] an existing system ( ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> � Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil leval is [x] or is not [ ] identified undar this septic system. If the <br /> saturated soil level is not identified, this classification is subjact to revision.) <br /> TANK CONDITION (5-9) : 10 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [X] water tight or the condition is � ] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : failing <br /> COMMENTS: The septic system is classified as a failing system since the tanks have no bottoms. <br /> The system must be repaired, replaced or connected to municipal sewer by 12/31/2004. <br /> (Municipal sewer may or may not be available to you. ) <br /> �-///�/� -----J <br /> Date of Inspection Se ^c System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />
The URL can be used to link to this page
Your browser does not support the video tag.