My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
H
>
Heritage Lane
>
1000 Heritage Lane - 10-117-23-14-0005
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:19:39 PM
Creation date
1/23/2017 3:26:24 PM
Metadata
Fields
Template:
x Address Old
House Number
1000
Street Name
Heritage
Street Type
Lane
Address
1000 Heritage Lane
Document Type
Septic
PIN
1011723140005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � <br /> S�� T,�STING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br /> 951 Katydid Lane NE • St. Michaei, MN 55376 • (612) 497-3566 <br /> b <br /> September 24 , 1993 �.�A,�� <br /> , <br /> Garth Johnson <br /> 1000 Heritage Lane <br /> Orono, Henn. Co. , MN <br /> This On-Site Sewage Treatment System is Designed for a Type l, four <br /> bedroom home in accordance with the Minnesota Pollution Control <br /> Agency Chapter 7080 and local ordinances . <br /> The soils on this site are SCS soils mapped - HeB - Heyder sandy loam <br /> & LrB - Lester loam. A seasonally high water table was not present <br /> in the area of the proposed system. <br /> This site has an existing non-conforming system due to a seasonally <br /> high water table less than 36" below the bottom of the treatment <br /> area, fill soils & in a drainage pattern. The existi�g tanks are <br /> recorderd at the city as block type and will need to be abandoned, <br /> pumped & filled with soil . <br /> The soils at a depth of 30" have a percolation rate averaging <br /> 11. 5 min/inch. A Standard Trench System may be installed. <br /> A pumping chamber will need to be installed to lift the effluent <br /> to the treatment area. <br /> The power supply and switches must be located outside the manhole and <br /> pumping chamber in a weather proof enclosure. A warning device must <br /> be installed with a light and sound device, this is in case of a pump <br /> failure. Mercury floats are a good method. The supply line pipe <br /> must have back drainage to the pumping chamber. <br /> All neighboring wells are located greater than 75 ' away from the <br /> proposed treatment area. <br /> CONT ' D <br />
The URL can be used to link to this page
Your browser does not support the video tag.