Laserfiche WebLink
� O� <br /> � O <br /> iOja, � <br /> � ,# ,�1���;� ,� CITY o� ORONO <br /> � �_.r �� <br /> �`,,� ���������� ��l4 Municipal Offices <br /> .L '� ,,';���� �,��� Street Address: Mailing Address: <br /> 9 �r��� .¢, <br /> kEBH� 2750 Keiley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: _� � Address: 1515 Green Trees Rd. <br /> o��(�'� T� <br /> Permit #'s: 369, 6736 Dates: 9/4/63, 7/B/B2 Contractors: Minnatonka Saptic, Widmer <br /> Bros. <br /> (This is [x] an existing system [ ] new construction) . <br /> STEM COMPLIANCE (1-3) : 1 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil leval [� has or [ ) has not baen identified at this tima. If the <br /> saturated soil level has not been idantifiad, this classification is subject to ravision.) <br /> TANK CONDITION (5-9) : 6 <br /> 5 Pumpout not needed at this time. <br /> � Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintanance Pumpout tha tanks [ ] were or [� ware not confirmed <br /> to be watertight by the licansad pumping contractor. If the tanks were not confirmad to be <br /> watertight, this classification is subject to ravision.) <br /> D AINFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : madium <br /> COMMENTS: <br /> �/ � <br /> Date of—�pection Se ic System Inspec or <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telep6one (612) 473-7357 • FAX 473-0510 <br />