Laserfiche WebLink
� <br /> • . ti�-1� �������''.'T .�a� ����. <br /> , �51 KATY�f D LA!�E <br /> � ST. M'CHAEL, MN 55376 <br /> 497-3566 <br /> S}even .�., Schirmers .. <br /> r . <br /> October �2 , 1989 <br /> Johr_ Tur:���acer <br /> Lot 5, I31ock 1 & �u�lot D <br /> Green Trees on `"ar_:_.��er Lake <br /> Orono, Henn. Co. , '.�:N �� <br /> This system is Des�gned for a Type 1, four be�room home and in accordance <br /> with the Minnesota Pollut,�on Control Agency Chapter 7080 and local <br /> ordinances . <br /> , The soils on this site are typical of SCS soils mapped - �rB - Lester <br /> loam. N:ore typic:al of Heyder soils . A seasonal'_y high ��,�ater table <br /> was located a*� 76" & 82" , (mottled soil ) . The bottom of each trench <br /> must be located at 1Past 3 ' above tne seasonally high water tab?e. <br /> A standar� t.rench systecn may be ins�a'le�. <br /> The scils at a �eoth . of 3"" have a percolation rate averaging 3 . 2 <br /> min/inch a�d are adequate for +�reating sep`ic effluent. <br /> A�1 neigh�aoring wel'_s are located more th�*� �QO ' away from the proposed <br /> treatment area . . <br /> Keen all heavy equip� nn'� off of t'�e pro?�osed treatment area before and <br /> after construction as much as poss�ble . The treatment area shoulc� be <br /> marked off before construct�on. <br /> With prooer �nstallation and maintenance, this system should have no <br /> problem in treating septic effluent e�fectively. <br /> Recommend to puTp the sep}ic tank every year �if there is only 1 tank <br /> & every 2 years if there are 2 }anks . <br /> � �,�— _� . �r iC <br /> � �� <br /> Steven � . Schirmers �S <br /> S3S/ds :':;' and f'ercolativn Te�ts <br /> Septic Syetem. �eaign <br />