Laserfiche WebLink
- -o��� <br /> �. � . . . � <br /> 0 0 �,, <br /> �� - : . } CITY of ORONO <br /> , . <br /> ��.:j\�.•� Y`'.: . <br /> � 1 Y' . f�`�,'1 . . I ' � <br /> r�,, !� ,,�. .�G . �ti ' Municipal Offices <br /> � t., r "�'�G Street Address: �lSa-a49-�-1bo o Mailing Address: <br /> �'9$'EggOg' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �4�� �'«�" 1�«S w <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYST'EM CONFORMITY (1-3): I <br /> �1 "CODE SYSTEM" An ISTS which meets all the location,design and conswction standards of the current Orono Municipal Code. <br /> 2/ "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot sepazation requirement or rivo foot requ'vement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�ards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the luniting soil characteristics. <br /> TANK CONDITION(5-7): 6 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> � Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes. This ailows for the proper <br /> cieaninQ. Keep water softner and iron tilter discharge out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workinQ in your house. The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> � Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> � �..��.Q�(� .�v�.., p 5( -j-,�L <br /> COMMENTS: N , I�a k S �'� - f P ��� <br /> S v r.-r-�� �c�o�' � <br /> � _�—�� � al�C ����`-1 <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisf'y the requirements for a mortgage or other transfer of property. be advised that this report does <br /> not �uarintee or certif} that an existing system �vill continue to function properl}. but is merely an opinion of the adcquac�• of thz s�stem wtder current <br /> cundition;bascd on the a��ailablc infbrnlation. <br />