My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00891 - mound septic
Orono
>
Property Files
>
Street Address
>
G
>
Graham Hill Road
>
3375 Graham Hill Road - 05-117-23-11-0018
>
Septic
>
2015-00891 - mound septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:15:47 PM
Creation date
1/17/2017 12:09:47 PM
Metadata
Fields
Template:
x Address Old
House Number
3375
Street Name
Graham Hill
Street Type
Road
Address
3375 Graham Hill Rd
Document Type
Septic
PIN
0511723110018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> r � ' � <br /> 2015 purplecode Mound Design <br /> www.SepticResource.com {vers 12.6) <br /> Property Owner: Wooddale Builders Date: 4/2b/2015 <br /> Site Address: Lot 1, Blk.1, Graham Hill, Orono p�p; <br /> Comments: <br /> instructions: � = site specific input � =adjust if desired � =self-calculated (DO NO7 ADJUST) <br /> �� �5 bedroom Type � Residential System <br /> 2� 750 GPD design flow <br /> 3> No Garbage disposal ar pumped to septic <br /> a> 2500 Gal Septic tank {code minimum} 2500 Gal Septic tank {design size / LUG req'd) <br /> Tank options: none <br /> s> 1.2 GPD/ft2 mound sand loading rate <br /> 6> 10 ft rockbed width 62.5 ft rockbed length <br /> �> 3.0 ft latera!spacing 3.0 ft perforation spacing (maximum of 3 for both} <br /> end feed rrtanifold connection <br /> g) �laterals 60.5 feet long 21.0 perfs / lateral 63 perfs total <br /> (1/2 a perf ineans the first perf starts at the middle feed manifold) <br /> 9� 1/4" inch perfs at �feet residual head gives 0.74 gpm flaw rate per perforation <br /> for this perf size Fz spacing, �x pipe size on line 12, max perfs/lateral= 25 , tine#8 must be less --> OK <br /> ia� 4.0 doses per day (4 minimum) <br /> >>> 188 gallons per dose (treatment volume} <br /> iz� 2.Oa inch diameter faterals (or smaEler) will meet"5x pipe volume" <br /> 2.00 inch diameter laterals (or smaller) must 6e used to meet"4x pipe volume" requirement <br /> 2.00 inch diameter iaterals (or smaller) will meet"3x pipe volume" <br /> i3y 25 feet of 2.0 inch supply line leads to �gailons of drainback volume <br /> (Tip: "top feed"manifold to control the drainback) <br /> ia� 192 gallons 70TAL pump out volume (treatment+drainback) <br /> is> 6 feet vertical lift from pump to dispersal area, teads to a: <br /> i6} 47 GPM C� 13 feet of head, Pump requirement (note: >SOgpm may require an extra 3-6'of head) <br /> ��� 1250 gal Dose tank (code minimum) 125� gal Dose tank (design size / LUG req'd} at 20.00 gpi <br /> leads to a , <br /> is� 9.6 inch swing on Demand fioat, or timed dosing of 4.1 min ON (confirm pump rate with drawdown <br /> (to deliver Average flow, 66%of Peak design#low) B9 hrs OFF test and adjust as necessary) <br /> i9� 12 inches from bottom of tank to "Pump OFF"float <br /> 20� 22 inches#rom bottom of tank to"Pump ON"fioat, or 12 inches to'Timer ON"float if time dosed <br /> zi� 25 inches from bottom of tank to"Hi Level"float, or 35 inches to"Hi Level"float if time dosed <br /> zz� 750 gallons reserve capacity {after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.