Laserfiche WebLink
s. <br /> M <br /> City of Orono Septic System Approval <br /> ISTS DESIGN <br /> YES NO NA <br /> ISTS design specifications shall include proposed flows or other sizing information, minimum sewage tank <br /> capacity, minimum soil treatment area requirements,a plan of the component layout and all other information <br /> necessary to assure the City that the ISTS is designed and will be constructed to receive,treat and dispose of all <br /> of the sewa e from the buildin served. <br /> Setbacks <br /> Feature Sewa e Tank feet Soil Treatment Area feet <br /> Dee well 50 50 <br /> / Wetland 50 50 <br /> � General Develo ment Lake 75 75 <br /> /' Recreational Develo ment Lake 75 75 <br /> � Natural Environment Lake 150 150 <br /> r' Tributaries/Streams 75 75 <br /> � Drivewa s, sidewalks, decks and other hardcover 10 10 <br /> Pro ert lines, buildin s and buried i es 10 20 <br /> Lawn s rinkler s stems 10 10 <br /> Sewa e Tanks. <br /> Number of Bedrooms Tanks Liquid Capacities(gallons) <br /> 4 r less 1,000+ 1,000 re ardless of arba e dis osal use <br /> 5 0 6 1,250 + 1,000 re ardless of arba e dis osal use <br /> r- or 9 1,500 + 1,500 re ardless of arba e dis osal use <br /> 10 or more Sewa e tanks shall be sized as other establishments er MN Rules 7080. <br /> Pumping Stations. <br /> In order to standardize installation and electrical connection methods,the following pumping station requirements <br /> must be met in addition to MN Rules cha ter 7080 <br /> Electrical connection: <br /> A waterti ht, lockable electrical box must be mounted on a four-inch b four-inch treated redwood or cedar ost. <br /> All electrical connections shall be made within the box. Pump connection must not be made using a direct line <br /> � lu -in onl . Wire ent to the electrical box shall be sealed with a waterti ht material such as foam or utt . <br /> � Alarm and um floats shall be on se arate electrical circuits. <br /> Electrical wire from the power supply must not run over any tanks and must be laid beside the tanks and placed in <br /> � conduit alon the electrical ost. <br /> Electrical cords from the pump and floats must be run through a two-inch PVC(or equivalent)conduit(schedule <br /> � 80)with a one-inch gap between the conduit and the electrical box. Electrical cords must not run through or under <br /> the manhole cover. Wires must not have round contact. <br /> Pum in Chamber: <br /> Pressure pipe exiting the pumping chamber must be laid on a uniform slope up to the soil treatment area for <br /> proper drain back. The pressure pipe must be sleeved and inside a larger diameter pipe for additional support if <br /> spanning ground that has been excavated. If the pipe at the tank must be lower than union to get elevation for <br /> drain back, a one- uarter inch wee hole must be used. <br /> When soil depths above the pressure distribution pipe is less than 3'/z feet, insulation must be added to achieve <br /> / an insulating factor equal to 3'/z feet of soil to decrease the potential for freezing(Styrofoam or concentric piping <br /> are acceptable methods). Piping under hardcover, such as tennis courts or driveways shall be insulated pipe or <br /> e uivalent. <br /> � A reserve capacity equaling 75%of the anticipated daily flow must be allowed into the pumping chamber between <br /> the alarm activation level and the um tank inlet. <br /> Protection of drainfield area. <br /> Proposed drainfield areas shall be identified and marked off on the lot at the time of the site evaluation and prior to <br /> any construction or grading occurring in the area. The drainfield area shall remain undisturbed until drainfield <br /> construction is commenced. No vehicular traffic shall be allowed in the drainfield area either before or after <br /> drainfield installation. <br /> ACCEPTED DENIED y the Metro West on ehalf of the City of rono subject to existing regulations and the <br /> following conditions: /✓e�]�t.f /I•l �i f' �L �t*� �. c . <br /> Insp ctions required: Ss� ! �oi'f, <br /> x 1. �4�.l��' f /�o ���,v� — p2�� �a� 5. <br /> 2. �q.� o�/K � .,.. � f�wK a.f0 6. <br /> p( 3.�'i.,A � �svt� �►a.� �� M7. � 7. <br /> �. ` 2�.s� � a...� A .. C' �oet8. <br /> B : Printed Name: L m/Zb N IC O f7�V t��t! Date: � / <br /> w:\septic\septic system approval revised 2-2015.docx <br /> Page 2 of 2 <br />