My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00891 - mound septic
Orono
>
Property Files
>
Street Address
>
G
>
Graham Hill Road
>
3375 Graham Hill Road - 05-117-23-11-0018
>
Septic
>
2015-00891 - mound septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:15:47 PM
Creation date
1/17/2017 12:09:47 PM
Metadata
Fields
Template:
x Address Old
House Number
3375
Street Name
Graham Hill
Street Type
Road
Address
3375 Graham Hill Rd
Document Type
Septic
PIN
0511723110018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 � � <br /> Installer Summary <br /> 2500 galton Septic tank (minimum) Tank options: none <br /> 1250 �allon Dose tank {minimum) at 20.00 gpi <br /> 47 GPM C� 13 ft. of head, Pump required <br /> 9.6 inch swing on Demand float or 4.1 minutes ON time & ��hours OFF time <br /> 22 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float <br /> 25 inches from bottom of tank to"Hi Level Alarrri'float <br /> 25 ft. of 2.0 inch supply line with end feed manifold connection <br /> • (7ip: "top feed" manifold to control drainback) <br /> 18 inch, or 1.5 ft. Sand Lift Mound <br /> 10 ft. wide by 62.5 ft. long Rock bed <br /> 3 laterals 2.00 inch diameter 60.5 ft. long 3.0 ft. lateral spacing <br /> 1/4" inch perfs 3.0 ft. pertoration spacing <br /> No Effluent filter Fz alarm <br /> 3 ctean out£t valve box assem6lies <br /> 27.0 ft.Tota[sand ABSORPTION width (sand beyond rockbed) (minimum) <br /> 0.0 ft. upslope and sidestope <br /> 17.0 ft. Downslope <br /> Specific slope ratios give BERM widths (topsoil beyond rotkbed)of: <br /> 4:1 upstope ratio 90 ft. upstope berm <br /> 4:9 sidesiope 18 ft. sideslope berms <br /> 4:1 downslope 30 ft. downslope berm <br /> 4" inspection pipe <br /> 1$" cover �n tap <br /> Upsto e berm �� Do4vnsto e berm 30 <br /> 12" cover an sides <br /> �r�--'''�� � �(S"loarny cap&6"topsoil) <br /> 1.5 Ctear� s�r�rl lift <br /> --.. <br /> .. 1.5 De��h tra LiiYiitif�� <br /> Lirr�iti�-�� Conr#if_�on..__ _.�`_� �-- .�..__ _ ---_._.� <br /> Absor tion Width 27.0 ���—-���'_ �-_���__ _--.��.. <br /> N�te: <br /> Fnr 0 ta 1:� slc�pes, A,6sorption Wtdth is meas�ired frt�m the Bedeq��alty in bath directions. <br /> For sEapes >1�, Absvrptfon Wir�th is mQasur�d dc�wnttitl fram the upslope ed�e of th� B�d. <br /> Rock Bed: 28 yd3 or"1.4= 39 ton 9 in�hes under pipe <br /> Mound Sand: 278 Yd3 or"1.4= 389 ton calculation based on 3:1/4:1 stape from top of rockbed <br /> Loamy Cap; g7 yd3 or'1.4= 136 ton 6"deep <br /> Topsoil: 110 yd3 or`1.4= 154 ton b"deep <br />