My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01052 - pool
Orono
>
Property Files
>
Street Address
>
G
>
Graham Hill Road
>
3375 Graham Hill Road - 05-117-23-11-0018
>
Permits/Inspections
>
2015-01052 - pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:15:48 PM
Creation date
1/17/2017 12:09:03 PM
Metadata
Fields
Template:
x Address Old
House Number
3375
Street Name
Graham Hill
Street Type
Road
Address
3375 Graham Hill Rd
Document Type
Permits/Inspections
PIN
0511723110018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� • - - . , r.b1�F� <br /> . , • ,� � <br /> � <br /> '� -,�;� Pr'afessi4na� Service Indusfiri <br /> � ' Pit�sburgh Testin L �S' �nC. <br /> . g aboratory Division <br /> 'TEs'1'EO FOR: Cowr-Fon1a, Itta , <br /> A7�: ��, ���ak PftOJECT: Pool Caver Safery Tests <br /> 66 E�st 3335 South <br /> S�It L�ke Cky, Utoh At115 <br /> DA1'�: Au�ust 19, 1993 <br /> OUR R�PQRT' NO» 7Q6-30110.001 <br /> On August 16, 1993, professional Service fndustries was cont3ctc�ct by Cover-Pools, inc, and asked that <br /> PSi revfew ASTM Standard � 13�46..g1 to see if tesb performed by, pS� ;n May �nd June ot 1990 m�et <br /> the siandard perforrnance Sp�ci�tton of ASTM F1346-91. Th� standard was reviewed, and tests <br /> performed by PS( meet the requlr�ment� of AS7M F1346-91. The foflowfng Is a repori issued by PSl <br /> to Cover pnols, lne. �of Poot Cover Safety tesis Whrch meet the criteria of ASTM F1346-91 (forme�iy <br /> � AS'1`M �513). <br /> On May 31, 199Q, a representaWe of Profession�l Service (ndustr�es was at the Corporate Offices of <br /> Caver-Poofs, lnc, iocated at• 69 East 3335 South, 3aft Lake Cfty, Utah &3115, to perfnrm safety <br /> requirements tests on Cover-Poofs, Inc.,Savc�-T-Cover II safety covers. 'i'�e safety tosts perfarmed were <br /> in accordance with �1S"fh1 ES 93, Emer�encyr Standarc! Performancs Speci�icatian for Safery Covers and <br /> �Labeling Requirements for a)1 covers for SwimmiRg Pools, Soas and Not Tubs. <br /> A 16' x 32' pUof was lflcated at.the Corporate Otfices of Cover-Paols, inc. The pool was equipped wrth <br /> an under track Cov�r-pool safety caver and top track (universalJ�Cov�r-Pool safety cover. ThQ trac�ing <br /> systems wer� connected ta a recfwwood deck, with the connections at Ewo feet on center along the length <br /> of the deck The safety cover fabric used in the under tracic system had a pnys(cal property oi 16.2 <br /> oz/sq. yd. The safety cover fabrtc used in the top track system had a physical pmperty of 13.2 oz/sq. <br /> yd. <br /> STA?1C LOAD 'T'EST <br /> The stattc load test was conducted on both Crner-Ponl safety covers in aa:ordance with <br /> s�ct}on 9.1 of AS7M ES 13. The� wQights usad w�re welghed using a cafibrated scafe <br /> which is traceable to !h� Nationt�l Bureau af Standards. The three weights used each <br /> had an area of one squate fQot. One wefght wGighed 51.0 Ibs., one 210.1 ibs. and one <br /> 226.3 Ibs. Tt�e tatal weight used fdr the statfc load tests was 487.4 tbs. Three points <br /> were tested for static load on each Cover-Poof safery cover. The locatiens of the thr�e <br /> points are as�fallows: • <br /> 4' from the end nf the pooi in the,center. <br /> 10' from the end of the poo! (n the center and in the cenier of the pool. <br /> Both Cover-Poof safety cvvers met the performance requirements for the stat(c foad test <br /> as ouUined in A5'T'M �S 13 sectinn 7.]. � <br /> 2955 South Wost Temple Streel • Sa1l Lake Ctty, UT 84115 • 80t/48a•g827 • Fax 801/487•3312 <br />
The URL can be used to link to this page
Your browser does not support the video tag.