Laserfiche WebLink
0,5lO6l2015 10:12 Riccar Heating �A�{}763 754 0132 P.005l009 <br /> R ccar Headnd andaCoo�ghtCommerclal�HVACLd'�de Elite, o re,f�evelopment,_Inc. <br /> g ° 8 , Wooddale 3mi(h Ftes, <br /> Andover MN 9630� P.a e a <br /> S sfem �1 Furnace And Air Summa Loads <br /> �OG11�On�nl � L�fE38 �'eo l.at S�n '�otai <br /> Deseri tiol7 Qaan Loss G�in G�in �.Gain <br /> Andersen: Cilazfng-operable wlndow, WOOC�9A9h, u-vafue 543_9 13,404 0 17,844 17,844 <br /> 4.29, SHGC 0.32 <br /> 10D�f: Glazing-French door, double pane low�glass(e= 24 857 0 8a9 849 <br /> 0.90), insulated flberglass frame, u-�alue 0.42, <br /> sH�c o.3a <br /> 11N: Door-Meta1- Polystyrene Core 20.4 607 0 971 171 <br /> 11 Q: Door-Metal-Polystyrene Core With Storm 2$ 500 b 141 1a1 <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 191'[.2 10,569 0 1,652 1,652 <br /> cavity, no bo�rd insulatian, siding finish,wood studs <br /> 15B0-10sf-8:Wall-Basement, , R-10 board insulation to 997.5 4,911 b 187 187 <br /> flaor, no in#eriar finish, 8'fl�or depth <br /> iBB-50: Roof/Ceiling-UnderAtticwith Insulation on Akdc 1952 3,318 0 1,874 1,874 <br /> Flaor(also use for Knee Walls and Partition <br /> Ceilings),Ven#ed Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Da�k Metal,Tar and Grav�l or <br /> Membrane, R-50 fnsulatlon <br /> 218-32: Flpor-Basement, Concrete slab,any thlckness, 2 1921 2,Z86 0 0 0 <br /> ar more faet below grade, R-3 or higher insulation <br /> installed below floar, any floor cover, sho�test sida of <br /> floor slab is 32'wlde <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 31 92 0 9 9 <br /> R-30 b(anket Insulation, any cover <br /> 5ubtotals for structure: 36,536 D 22,727� 22,727 <br /> Peopl�: 5 1,000 1,950 2,150 <br /> Equipmant: 0 3,401 3,001 <br /> Llghting: D 0 0 <br /> Ductwork: 0 0 0 Q <br /> Infiltration: Winter CFM:67,Summer CFM: 38 6,Q98 561 503 1,0B4 <br /> Ventilation:Winter CFM: 748, Summer CFM: 148 5,370 2,286 821 3,917 <br /> Exhaust: Winter CFM; 148, Summer CFM: 148 <br /> Humidiflcatlon(Winter)8.88 AaUday: 3,624 0 0 0 <br /> AEp F�ccursion____ , _..__.^_.-------- - -- 0 0 2,Q9'i ------ 2�091 <br /> Syst�m � Furnace And Alr Load Totals: 51,628 3,857 30,294 3a,1 fi0 <br /> C e� Fi ure� ' " <br /> Supply CFM: 1,381 CFM Per Square ft.: p.357 <br /> Square ft.of Rodm Area: 3,873 <br /> Volume(ft')of Cond. Spec�: 39,691 <br /> ,S. s.i�`m I�o d� ;�,. <br /> Total Heating Required Including Ventilation Air; 51,fi28 Btuh 51.628 MBH <br /> Total Sensibla Gain: 30,294 �tuh 89 °k <br /> To#al Latent Gain: 3,857 Btuh 11 �O <br /> Total Caoling Required Including Ventilation Air: 34,150 Btuh <br /> ,N�"t�s °` ` • <br /> i�h�aa is an ACCA approved Manual J and Manual d computer program. <br /> Calculations ere performed per ACCA Manual J 8th Edftlon,Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that me�ts both sensible and latent loads eccording to the manufacturer's performance ds#a et <br /> your design canditions. <br /> C:1...1Wooddale 5mith system braakdown..rh9 Wednesday, May O6,2015, 9:40 AM <br />