Laserfiche WebLink
New Construction Ener Code Com liance Certificate �!\ <br /> JY P ��� ���� <br /> Per N1101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside Date Certifica�e Poscea <br /> the building. The certificate sl�all be completed by the builder and shall list information and values of /" . <br /> components listed in Table N1101.8. _ <br /> Mailing Address of the Dwelling or Dwelling Unit City <br /> 3375 Graham Hill Road Orono WOODDALE <br /> s u i � o E a s <br /> Name of ResidenNal Contractor MN License Number <br /> Wooddale Builders BC002926 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> 0 <br /> � � <br /> a <br /> � � �' Active(Wiih fan and monometer or <br /> � � -o o � other system monitoring device) <br /> � a <br /> �o fl. 3 .�'. �j — o -d � <br /> � R O � N � <br /> 7 d Q� 0] � U a� b C <br /> � T <br /> ? � O vi N O Q G. j( O <br /> Insulation Location � .° z � � U O � w <br /> ce o � m a`� �v � <br /> � � � � � � � � <br /> f= � Z w w r° c° � C � Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-15 X ext.2"certa-foam-int.3/4"thermax <br /> Perimeter of Slab on Grade X <br /> Rim,To�st(Fou�dat�on) R-20 X 3 1/4" spray foam <br /> Rim Joist(lst Floor+) X <br /> weu R-21 X <br /> Ceiling,flat R-49 X <br /> Ceiling,vaulted R-49 X <br /> Bay Windows or caatilevered areas R-38 X AISO 3/4"foam below <br /> Bonus room over garage X <br /> Describe otherinsulated areas <br /> Windows 8 Doors Heating or Cooling Ducfs Oufside Condifioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 0.30 X Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 029 R-value=r8 w/vapor barrier <br /> MECHANICAL SYSTEMS Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type Nat. Gas Electric Electric Passive <br /> Rheem Triangle <br /> Manufacturer Tube Trian le Tube Rheem Powered <br /> Interlocked with exhaust device. <br /> R96VA0702317MSA Describe: <br /> R96VA0851521 MSA 13AJ N36A01 <br /> Model Prestige Solo 110 Smart 80 13AJN42A01 <br /> Input in 70,85,30- Capaciry in gp Output in 3&3.5 Other,describe: <br /> Rating or Size BTliS: 1�p Gallons: Tons: <br /> Heat Loss: 104,823 Heat 73,349 Location of duct or system: <br /> Structure's Calculated Gain: <br /> AFUE or 96,96,95 SEER: 13 for both <br /> HSPF% <br /> Calculated 34200 & <br /> cooling load: 41000 <br /> Efficienc Cfm's <br /> "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up fumace): X Not required per mech.code <br /> Select Type Passive <br /> 2 Heat Recover Ventilator(HRV) Capacity in cfins: Low: 75,50 High: 150,98 Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfins: Low: High: Location of duct or system <br /> Continuous exhausting fan(s)rated capaciry in cfrns: <br /> Location offan(s),describe� L.L.Bath Cfm's � <br /> Capacity continuous ventilation rate in cfrns: 74,4$ "round insul duct <br /> Tota]ventilation(intermittent+continuous)rate in cfms: 148,95 "metal duct <br />