My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-00731 - septic mound system
Orono
>
Property Files
>
Street Address
>
G
>
Graham Hill Road
>
3340 Graham Hill Road - 05-117-23-11-0012
>
Septic
>
2012-00731 - septic mound system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:15:35 PM
Creation date
1/12/2017 3:09:49 PM
Metadata
Fields
Template:
x Address Old
House Number
3340
Street Name
Graham Hill
Street Type
Road
Address
3340 Graham Hill Rd
Document Type
Septic
PIN
0511723110012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Design Summary Worksheet "�' <br /> Minnesota Pollution UNIVERSITY <br /> ControlAgency OF MINNESOTA , .�,��� <br /> Property Owner/Client: Stonewood LLC. <br /> site address: 3340 Graham Hill Road (Site E) <br /> 1. AVERAGE DESIGN FLOW: <br /> A. Design Flow: 750 Gallons Per Ddy(GPD) Note: The estimoted design Jlow is considered a peak jfow rate including o w�ety <br /> factor.For long term performance,the average daily flow is recommended to be< <br /> B. Septic Tank capacity: 2250 Gallons bo%oj this value. <br /> �, Number of Septic Tanks or Compartments: � Eff(uent Screen&Alarm? YeS <br /> Type of Soil Treatment and Dispersal Area Type of Distribution <br /> Q Trcrxha �Bed Q Mound �Gravity Distribut'an QQ Pressure Distribution-Level � Pressure DistribuYamUnlevel <br /> Q At-Grade Q Drip Distribution <br /> System Type <br /> �Type I ❑Type II ❑Type III []Type IV ❑Type V <br /> 2. $ITE EVALUATION: <br /> A. Depth to Limiting Layer: 20 inches 1.7 ft <br /> B. Measured Percent Land 5lope: 14.0 % 0.0 <br /> C. Soil Texture: � LOdm Percolation Rate: �Minutes per Inch <br /> D. Soil Hydraulic Loading Rate: 0.60 GPD/ftZ E.Contour Loading Rate 12 Gal/ft <br /> 3. DESIGN SUMMARY <br /> Trench Design Summary <br /> Absorption Area �ftz Sidewall Depth �in Trench Width �in <br /> Total Lineal Feet �ft Number of Trenches � Maximum Trench Depth �in <br /> Bed Design Summary <br /> Absorption Area �ftz Media Below Pipe ��in Bed Length �ft <br /> Bed Width �ft Maximum Trench Depth �in <br /> Mound Design Summary <br /> Absorption Area 625 ftz Bed Length 63 ft Bed Width 10.0 ft <br /> Absorption Width 20,p ft Clean Sand Lift �,3 ft <br /> Upslope Berm Width $,p ft Downslope Berm Width 25,0 ft Endslope Berm Width 14.0 ft <br /> Total System Length g� ft Total System Width 43 ft <br /> At-Grade Design Summary <br /> Absorption Bed Width �ft Absorption Bed Length �ft System Height �ft <br /> Absorption Bed Area �ftZ Upslope Berm Width �ft Downsiope Berm Width �ft <br /> Endslope Berm Width �ft System Length �fl System Width �ft <br />
The URL can be used to link to this page
Your browser does not support the video tag.